Results 301 to 310 of about 15,796,631 (405)

Advantages and limitations of navigation‐based multicriteria optimization (MCO) in selectively sparing pharyngeal constrictor muscles in head and neck radiotherapy treatment planning

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose Sparing pharyngeal constrictor muscles (PCMs) during radiotherapy improves patient‐reported swallowing function. This study aimed to explore the feasibility of integrating knowledge‐based planning (KBP) with multicriteria optimization (MCO) in Eclipse v18.0 to selectively spare PCM, quantify the required trade‐off in prophylactic ...
Laura K. Howard   +3 more
wiley   +1 more source

Developing reference plans for evaluating global clinical trials credentialing and PSQA systems

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose To develop a practical framework for creating a diverse set of validated reference plans (varying in complexity) and implement a workflow to introduce beam modeling, calibration, and delivery errors into the reference cohort to test and compare various dosimetry audit methodologies.
Fre'Etta M. D. Brooks   +13 more
wiley   +1 more source

Thank you to The Lancet Global Health's statistical and peer reviewers in 2022

open access: yesThe Lancet Global Health, 2023
The Lancet Global Health Editors
doaj  

The edge visualization metric: Quantifying the improvement of lung SBRT target definition with 4D CBCT

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose Four‐dimensional cone‐beam CT (4D CBCT) incorporates oversampling of 3D data to reconstruct multi‐phase CBCT data sets representing distinct phases of the breathing cycle based on a diaphragmatic correlate of respiratory motion. Motion artifacts and blurring can be reduced relative to three‐dimensional cone‐beam (3D CBCT), allowing ...
Colton Baley   +4 more
wiley   +1 more source

Enhanced analysis of gating latency in 0.35T MR‐linac through innovative time synchronization of a motion phantom and plastic scintillation detector

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose This study aims to evaluate how different gantry angles, breathing rates (BPM), cine image speeds, and tracking algorithms affect beam on/off latency and the subsequent impact on target dose for a 0.35T MR‐Linac with a 6 MV FFF beam.
Mateb Al Khalifa   +4 more
wiley   +1 more source

Home - About - Disclaimer - Privacy