Results 191 to 200 of about 1,617,530 (358)

Assessing HyperSight iterative CBCT for dose calculation in online adaptive radiotherapy for pelvis and breast patients compared to synthetic CT

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose/objectives Recent technological advancements have increased efficiency for clinical deliverability of online‐adaptive‐radiotherapy (oART). Previous cone‐beam‐computed‐tomography (CBCT) generations lacked the ability to provide reliable Hounsfield‐units (HU), thus requiring oART workflows to rely on synthetic‐CT (sCT) images derived ...
Jingwei Duan   +7 more
wiley   +1 more source

Impact of enhanced leaf model on dose calculation accuracy in single‐isocenter multitarget stereotactic radiosurgery treatments

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose Single‐isocenter multitarget (SIMT) radiosurgery has become increasingly popular as advancement in planning and delivery systems have made this approach clinically viable. With targets varying in size and distance from isocenter, SIMT plans are highly complex with dynamic multileaf collimator (MLC) motion.
Hem Moktan   +3 more
wiley   +1 more source

JACMP 2015 – 2019

open access: yes
Journal of Applied Clinical Medical Physics, EarlyView.
Per. H. Halvorsen
wiley   +1 more source

Commissioning of Halcyon enhanced leaf model in the Eclipse treatment planning system: Focus on simple slit fields and VMAT dose calculation

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose The dual‐layer multileaf collimator (MLC) in Halcyon adds complexities to the dose calculation process owing to the variability of dosimetric characteristics with leaf motion. Recently, an enhanced leaf model (ELM) was developed to refine the MLC model in the Eclipse treatment planning system. This study investigates the performance of
Ryohei Miyasaka   +6 more
wiley   +1 more source

Impact of acceleration treatment on treatment plan and delivery qualities in tomotherapy for lung cancer

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Background Acceleration treatment (AT) is a novel treatment planning parameter introduced in the tomotherapy‐dedicated treatment planning system, Precision. This study explores the effects of AT on tomotherapy plans using helical (TomoHelical) and direct (TomoDirect) irradiation techniques.
Ryosuke Shirata   +9 more
wiley   +1 more source

Exploring surface‐guided systems for intelligent breathing‐adapted four‐dimensional computed tomography: A comparison to infrared‐based reflective marker systems

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose This study evaluates the technical feasibility of adapting a surface monitoring system, designed for conventional four‐dimensional computed tomography (4DCT), to an intelligent, breathing‐adapted 4DCT and examines its potential to expand the currently limited range of supported surrogate systems.
Niklas Lackner   +4 more
wiley   +1 more source

Home - About - Disclaimer - Privacy