Results 81 to 90 of about 1,009 (196)

Godiva and Juliet Diagnostics CED-1 (IER-176) [PDF]

open access: yes, 2011
A suite of diagnostics are being proposed for use in the Juliet experiment (IER-128). In order to calibrate and test the diagnostics prior to use, the LLNL calibration facility and Godiva pulsed reactor will be used to provide intense sources of neutrons
Scorby, J C
core   +1 more source

Development of an adjoint flux calculation technique for exact perturbation theory in Monte Carlo transport

open access: yesEPJ Nuclear Sciences & Technologies
A calculation technique computing the adjoint flux of perturbed system is developed for the exact perturbation theory in Monte Carlo transport. By using a correlated sampling and iterated fission probability methods together, the adjoint flux of ...
Jo Yunki, Lee Deokjung
doaj   +1 more source

Applicability of the first-order adjoint-weighted perturbation method for estimating beta-effective sensitivity to nuclear data

open access: yesNuclear Engineering and Technology
This study formulated equations in operator form using the first-order Adjoint-Weighted Perturbation (AWP) method. These equations are designed to calculate the relative change of reactor parameters—such as the multiplication factor (k), general reaction
Sung Hoon Choi
doaj   +1 more source

A Re-Analysis of Historical Los Alamos Critical Assembly Reaction Rate Measurements

open access: yesEPJ Web of Conferences, 2016
Starting in the 1950s and continuing into the early 1970s, a number of foil irradiations and fission chamber measurements were made in a variety of Fast critical assemblies at Los Alamos National Laboratory. These include (i) Godiva, a bare HEU spherical
Kahler A.C., MacInnes M., Chadwick M.B.
doaj   +1 more source

Evaluation of nuclear data using the Half Monte Carlo technique [PDF]

open access: yesEPJ Web of Conferences
The Total Monte Carlo (TMC) technique has proven to be a powerful tool to propagate uncertainties in nuclear data to the uncertainty in macroscopic quantities, such as neutron fluxes at detector positions and the criticality of reactor cores.
Andersson-Sundén Erik   +6 more
doaj   +1 more source

DOSE AND FLUX MEASUREMENTS ON GODIVA RADIATION EFFECTS EXPERIMENTS [PDF]

open access: yes, 1959
Flux and dose measurements of fast neutrons, thermal neutrons and gamma rays under perturbing conditions using Godiva as a source are described and discussed. The limitations of single monitoring devices are noted.
Harris, P.S.   +2 more
core   +1 more source

15. GoDiva Holliday: Nails

open access: yes, 2019
GoDiva Holliday gets ready for a fundraiser in Memphis, Tennessee by putting on stick-on nail polish.
Huff, Christina Alison
core   +1 more source

Initial validation of ALFRED: A Monte Carlo code built on Geant4 for TREAT energy deposition

open access: yesNuclear Engineering and Technology
Predicting the energy deposited in the specimen during an experiment in the Transient Reactor Test (TREAT) Facility is a complex problem due to the nature of the transients occurring in the reactor.
Paul A. Ferney, Nicolas P. Martin
doaj   +1 more source

41. GoDiva Holliday and DeePression Holliday: Parking Lot

open access: yes, 2020
GoDiva Holliday gets dressed in the South Rec parking lot in Oxford, Mississippi at the Drive-In Drag Show due to the Coronavirus pandemic.https://egrove.olemiss.edu/draginmississippi/1040/thumbnail ...
Huff, Christina Alison
core   +1 more source

Effect of reflected neutrons for fast pulsed reactor characteristics with metallic nuclear fuel

open access: yesHe jishu
BackgroundFast neutron pulsed reactors are sensitive to wall scattering neutrons, and their waveforms are changed by reflected neutrons. In addition, their operation may be adversely affected when there are too many reflected neutrons.PurposeThis study ...
GUO Shuwei   +8 more
doaj   +1 more source