Comparison of Goldmann applanation tonometer, Tono-Pen and noncontact tonometer in children
Background: To evaluate the agreement of Goldmann applanation tonometer (GAT) with Tono-Pen and noncontact tonometer (NCT) for measurement of intraocular pressure (IOP) in pediatric age group and to evaluate the correlation between central corneal ...
Usha Kaul Raina+4 more
doaj +6 more sources
Comprasion of ICare Rebound Tonometer and Goldmann Applanation Tonometer in High Myopia [PDF]
Purpose. To compare intraocular pressure (IOP) measurements with the Goldmann applanation tonometer (GAT) and the ICare rebound tonometer (RBT) in high myopic eyes. Patients and Methods.
Halil Huseyin Cagatay+4 more
doaj +6 more sources
Evaluation of agreement of IOP measurements by Tono-Vera tonometer to Goldmann applanation tonometry [PDF]
PurposeTo evaluate the accuracy of the new Tono-Vera rebound tonometer (Reichert Inc, Buffalo, NY) compared to Goldmann Applanation Tonometry.MethodsThis prospective, observational, cross-sectional study was designed in accordance with ANSI Z80.10-2014 ...
Charles R. Niles+3 more
doaj +3 more sources
Rectifying calibration error of Goldmann applanation tonometer is easy!
Purpose: Goldmann applanation tonometer (GAT) is the current Gold standard tonometer. However, its calibration error is common and can go unnoticed in clinics. Its company repair has limitations.
Nikhil S Choudhari+8 more
doaj +5 more sources
Factors associated with fluctuations in repeated measurements of intraocular pressure using the Goldmann applanation tonometer in Japanese patients with primary open-angle glaucoma [PDF]
Kiyoshi Yaoeda,1,2 Atsushi Fukushima,1 Motohiro Shirakashi,3 Atsushi Miki,4 Takeo Fukuchi2 1Department of Ophthalmology, Yaoeda Eye Clinic, Nagaoka, Niigata, Japan; 2Division of Ophthalmology and Visual Sciences, Niigata University Graduate School of ...
Yaoeda K+4 more
doaj +4 more sources
Intraocular pressure correlation to progressive retinal nerve fiber layer loss in primary open angle glaucoma as measured by standard and modified goldmann applanation tonometers [PDF]
Purpose Characterize the relationship between intraocular pressure (IOP) as measured by standard and modified Goldmann prisms and the progressive loss of retinal nerve fiber layer (RNFL) in a cohort of glaucoma patients.
Sean McCafferty+3 more
doaj +3 more sources
Evaluation of rebound tonometer iCare IC200 as compared with IcarePRO and Goldmann applanation tonometer in patients with glaucoma [PDF]
Background This study investigated the agreement between a new rebound tonometer, IC200, and IcarePRO and Goldmann applanation tonometry (GAT). Methods This was a prospective cross-sectional study.
Shunsuke Nakakura+7 more
doaj +2 more sources
Evaluation of the New Digital Goldmann Applanation Tonometer for Measuring Intraocular Pressure [PDF]
Purpose. To compare a new digital Goldmann applanation tonometer (dGAT) that measures intraocular pressure (IOP) in 0.1 mmHg increments to a standard Goldmann applanation tonometer (sGAT). Methods. This study included 116 eyes of 60 subjects.
Yuta Sakaue+6 more
doaj +2 more sources
Agreement among Goldmann Applanation Tonometer, Easyton Transpalpebral Tonometer, Tonopen, and Icare in Patients with Keratoconus. [PDF]
Yildiz MB+5 more
europepmc +2 more sources
A Comparative Study Between the Goldmann Applanation Tonometer and the Non-Contact Air-Puff Tonometer (Huvitz HNT 7000) in Normal Eyes. [PDF]
Stock RA+4 more
europepmc +3 more sources