Do Ophthalmology Residents Know How to Check the Calibration of a Goldmann Applanation Tonometer? [PDF]

open access: green, 2022
Aaron Carlisle   +4 more
openalex   +1 more source

Comparison of dynamic contour tonometry (Pascal®) with pneumotonometry and Goldmann tonometry [PDF]

open access: yes, 2007
To compare the intraocular pressure measurements as defined by the Pascal tonometer, the Goldmann tonometer and the pneumotonometer. METHODS: This was an observational clinical study, which included two hundred and five randomly ...
Heras-Mulero, H. (Henar)   +3 more
core  

Corneal Biomechanics in Ectatic Diseases: Refractive Surgery Implications. [PDF]

open access: yes, 2017
BACKGROUND: Ectasia development occurs due to a chronic corneal biomechanical decompensation or weakness, resulting in stromal thinning and corneal protrusion. This leads to corneal steepening, increase in astigmatism, and irregularity.
Ahmed Elsheikh   +97 more
core   +1 more source

Goldmann tonometry tear film error and partial correction with a shaped applanation surface

open access: yesClinical Ophthalmology, 2018
Sean J McCafferty,1–4 Eniko T Enikov,5 Jim Schwiegerling,2,3 Sean M Ashley1,3 1Intuor Technologies, 2Department of Ophthalmology, University of Arizona College of Medicine, 3University of Arizona College of Optical Science, 4Arizona Eye ...
McCafferty SJ   +3 more
doaj  

The intraocular pressure response to dehydration: a pilot study [PDF]

open access: yes, 2011
This study was designed to determine the Intraocular Pressure (IOP) response to differing levels of dehydration. Seven males participated in a 90 minute treadmill walk (5 km/h and 1 % grade) in both a cool (22 °C) and hot (43 °C) climate. At Baseline and
Feigl, Beatrix   +2 more
core   +2 more sources

A survey of current and anticipated use of standard and specialist equipment by UK optometrists [PDF]

open access: yes, 2014
Purpose: To investigate current and anticipated use of equipment and information technology (IT) in community optometric practice in the UK, and to elicit optometrists' views on adoption of specialist equipment and IT.
Amin M   +13 more
core   +1 more source

Evaluation of the agreement and reliability of Transpalpebral Tonometers compared with Goldmann Applanation Tonometer - A systematic Review and Meta-Analysis Protocol. [PDF]

open access: yesIndian J Ophthalmol, 2023
Jerrome S   +7 more
europepmc   +1 more source

Avaliação das técnicas de antissepsia bacteriana do cone de aplanação dos tonômetros de goldmann em uso em consultórios e Hospitais da grande Florianópolis. [PDF]

open access: yes, 2006
Trabalho de Conclusão de Curso - Universidade Federal de Santa Catarina. Curso de Medicina.
Daguano, Carolina Rottili
core  

Correlations between corneal biomechanical properties measured with the ocular response analyzer and icare rebound tonometry [PDF]

open access: yes, 2008
Purpose: To investigate the biomechanical properties of the normal cornea, and correlate them with central and peripheral corneal thickness and age. Methods: Seventy-six right eyes of volunteers were measured with Ocular Response Analyzer (ORA), ICare ...
Fernandes, Paulo Rodrigues   +4 more
core   +1 more source