Results 21 to 30 of about 3,560 (179)

Comparison of three methods of tonometry in normal subjects: Goldmann applanation tonometer, non-contact airpuff tonometer, and Tono-Pen XL [PDF]

open access: yesClinical Ophthalmology, 2014
Ihsan Yilmaz, Cigdem Altan, Ebru Demet Aygit, Cengiz Alagoz, Okkes Baz, Sibel Ahmet, Semih Urvasizoglu, Dilek Yasa, Ahmet DemirokBeyoglu Eye Training and Research Hospital, Istanbul, TurkeyObjective: We aimed to compare intraocular pressure (IOP ...
Yilmaz I   +8 more
doaj   +2 more sources

Comparison of Intraocular Pressure Using Goldmann's Applanation Tonometer as the ‎Current‏ ‏Standard of Clinics with Five Different Tonometers in Healthy People [PDF]

open access: yesJournal of Paramedical Science and Rehabilitation, 2022
Purpose:To compare the intraocular pressure (IOP) measured with the Goldmann tonometer as the current standard of clinics with five different tonometers in healthy people, and to investigate the effect of corneal thickness and biomechanical properties on
H Momeni-Moghaddam   +6 more
doaj   +1 more source

Comparison of a new non-contact tonometer with Goldmann applanation [PDF]

open access: bronzeEye, 1989
A comparison of a new non-contact tonometer (Keeler Pulsair: Keeler UK Ltd) with the Goldmann applanation tonometer is reported. Measurements of intraocular pressure were obtained from 182 eyes of 94 patients. At low pressures (less than 10 mmHg) the candidate tonometer tended to overestimate pressures obtained with the Goldmann tonometer whilst at ...
M J Moseley   +2 more
openalex   +4 more sources

Comparison of transpalpebral tonometer with Goldmann applanation tonometer

open access: diamondTaiwan Journal of Ophthalmology, 2014
AbstractTranspalpebral tonometer, a new generation intraocular pressure (IOP) measuring instrument is nowadays used for self-tonometry. It is convenient and noninvasive and seems suitable for IOP measurement at home, as recommended by several authors.
A. K. Chakraborty   +2 more
openalex   +3 more sources

Clinical comparison of the ProTon and Tono-Pen tonometers with the Goldmann applanation tonometer. [PDF]

open access: bronzeBritish Journal of Ophthalmology, 1994
A clinical evaluation of a new electron ProTon tonometer was performed comparing the values of intraocular pressure (IOP) measured using this instrument with those determined by a similar instrument, Tono-Pen XL, and by Goldmann applanation tonometry. The mean IOP measured in 106 eyes with the ProTon tonometer was not significantly different from that ...
Anna Midelfart, Andreas Reidar Wigers
openalex   +5 more sources

Systematic Review of the Agreement of Tonometers with Goldmann Applanation Tonometry [PDF]

open access: yesOphthalmology, 2012
To assess the agreement of tonometers available for clinical practice with the Goldmann applanation tonometer (GAT), the most commonly accepted reference device.A systematic review and meta-analysis of directly comparative studies assessing the agreement of 1 or more tonometers with the reference tonometer (GAT).A total of 11 582 participants (15 525 ...
Cook, Jonathan Alistair   +8 more
openaire   +6 more sources

Comparison of Diaton transpalpebral tonometer with applanation tonometry in keratoconus [PDF]

open access: yesInternational Journal of Ophthalmology, 2016
AIM: To investigate the added value of using a Diaton transpalpebral tonometer (DT) to measure IOP in keratoconus. Most type of tonometers use corneal applanation or biomechanical resistance to measure intraocular pressure (IOP); however, these factors ...
Robert PL Wisse   +3 more
doaj   +1 more source

Clinical alert: damage to Goldmann applanation tonometer tips [PDF]

open access: bronzeActa Ophthalmologica Scandinavica, 2005
hen Goldmann first presentedhis new applanation tonometerin 1955, he emphasized that cross-infection by corneal contact with themethylmethacrylate-covered biprismmight occur and that appropriate dis-infection should be carried out (Gold-mann 1955).Schmidt & Lebek 1971 recom-mended soaking the tip in 5% for-maldehyde as the safest procedurefor the tip ...
Christoph Kniestedt   +2 more
openalex   +4 more sources

Analysis of glaucoma genes in Finnish patients with juvenile open‐angle glaucoma

open access: yesActa Ophthalmologica, Volume 101, Issue 7, Page 797-806, November 2023., 2023
Abstract Purpose To identify germline variants in myocilin (MYOC) and other known monogenic glaucoma genes in Finnish patients with juvenile open‐angle glaucoma (JOAG). Methods Finnish patients with JOAG treated between 2010 and 2018 at the Department of Ophthalmology, Helsinki University Hospital, Finland, were enrolled.
Perttu J. Liuska   +10 more
wiley   +1 more source

Home - About - Disclaimer - Privacy