Agreement of intraocular pressure measurement by scleral Schiotz and Goldmann applanation tonometer. [PDF]
Abstract Intraocular pressure (IOP) measured through the sclera has some advantages over IOP measured through cornea. This study aimed to determine the agreement between IOP as estimated by scleral Schiotz (SS) tonometer and Goldmann applanation tonometer (GAT).
Shaikh ZM +3 more
europepmc +4 more sources
Purpose The aim of this study was to determine the accuracy of the air-puff tonometer compared to the Goldmann applanation tonometer (GAT) and Schiotz tonometer.
Khalil M. Khalil +3 more
doaj +2 more sources
Comparison of intraocular pressure adjusted by central corneal thickness or corneal biomechanical properties as measured in glaucomatous eyes using noncontact tonometers and the Goldmann applanation tonometer. [PDF]
Yaoeda K +3 more
europepmc +3 more sources
Purpose: To assess and compare the intraocular pressure (IOP) with a non contact tonometer (NCT) versus a goldmann applanation tonometer (GAT) in relation to the central corneal thickness (CCT). Materials and Methods: The study was conducted on 102 eyes.
B. Aisha Sarfunissa +3 more
doaj +2 more sources
Agreement between rebound (iCare IC200), Goldmann applanation tonometer, and noncontact (air puff) tonometer in the immediate postoperative period following vitrectomy. [PDF]
Rajagopal S +4 more
europepmc +2 more sources
Comparison of intraocular pressure measurement between Goldmann applanation tonometer and Tonopen
Background: Primary open-angle glaucoma (POAG) is a chronic optic neuropathy causing visual field loss and open angles. It accounts for 90% of glaucoma cases and is linked to raise intraocular pressure (IOP). POAG is the most common type of glaucoma.
Sabita Dhakal +3 more
doaj +3 more sources
Intraocular pressure correlation to progressive retinal nerve fiber layer loss in primary open angle glaucoma as measured by standard and modified goldmann applanation tonometers. [PDF]
McCafferty S, Shah M, Laul A, Kilgore K.
europepmc +2 more sources
Comparison of Intraocular Pressure Using Goldmann's Applanation Tonometer as the Current Standard of Clinics with Five Different Tonometers in Healthy People [PDF]
Purpose:To compare the intraocular pressure (IOP) measured with the Goldmann tonometer as the current standard of clinics with five different tonometers in healthy people, and to investigate the effect of corneal thickness and biomechanical properties on
H Momeni-Moghaddam +6 more
doaj +1 more source
Clinical Assessment of Automated Non-Contact Tonometer: Interchangeability with Goldmann Applanation Tonometry and Repeatability. [PDF]
Chaglasian M +7 more
europepmc +2 more sources
A new tonometer based on the application of micro-mechanical sensors [PDF]
An instrument for the measurement of intraocular pressure (IOP) is presented. It consists of a micromachined silicon sensor, which measures the diameter of a flattened part of the eye globe and simultaneously determines the smallest distance between the ...
Bergveld, Piet +2 more
core +10 more sources