Abstract Background This study aimed to evaluate the impact of PreserFlo Microshunt on the ocular surface, focusing on both objective and subjective parameters. Methods Prospective‐observational study on 48 eyes undergoing PreserFlo Microshunt implantation, standalone or combined with phacoemulsification.
Gloria Gambini+8 more
wiley +1 more source
Purpose. The primary objective of this study is to evaluate the efficacy and safety profile of PreserFlo MicroShunt implantation in the medium‐ to long‐term follow‐up of patients with open‐angle glaucoma. The secondary objective is to analyze laser flare meter (LFM) values before and after PreserFlo MicroShunt implantation. Methods.
Carlo Cagini+5 more
wiley +1 more source
Applanation tonometry: a comparison of the Perkins handheld and Goldmann slit lamp-mounted methods
R Arora,1 H Bellamy,2 MW Austin21University Hospital of Southampton, Southampton, Hampshire, 2Singleton Hospital, Abertawe Bro Morgannwg University Health Board, Swansea, Wales, UKPurpose: To compare intraocular pressure (IOP) measurements, taken using ...
Arora R, Bellamy H, Austin MW
doaj
Background: No consensus has been reached on the adequate dose of mitomycin C (MMC) in XEN45 gel stent implantation. Lower doses have the potential to reduce MMC‐linked side effects. This study aimed to evaluate treatment efficacy of ab interno XEN45 gel stent in primary open‐angle glaucoma (POAG) with three different MMC doses.
Felix F. Reichel+5 more
wiley +1 more source
Comparing intraocular pressures with different types of tonometers and its correlation with central corneal thickness in patients presenting in a tertiary care centre [PDF]
Background & Aims: Glaucoma usually undiagnosed in general population. People usually ignores the symptoms and came late when disease already get worsened. This study aimed to compare intraocular pressures in general population having inclusion criteria
Priyanka J.Kharadi+2 more
doaj
Guidelines for the management of open‐angle glaucoma
Acta Ophthalmologica, Volume 102, Issue 2, Page 135-150, March 2024.
Gauti Jóhannesson+7 more
wiley +1 more source
Agreement of intraocular pressure measurement with Corvis ST, non-contact tonometer, and Goldmann applanation tonometer in children with ocular hypertension and related factors. [PDF]
Li HG+9 more
europepmc +1 more source
Goldmann tonometry tear film error and partial correction with a shaped applanation surface
Sean J McCafferty,1–4 Eniko T Enikov,5 Jim Schwiegerling,2,3 Sean M Ashley1,3 1Intuor Technologies, 2Department of Ophthalmology, University of Arizona College of Medicine, 3University of Arizona College of Optical Science, 4Arizona Eye ...
McCafferty SJ+3 more
doaj
Effect of corneal parameters on measurements using the pulsatile ocular blood flow tonograph and Goldmann applanation tonometer [PDF]
Pinakin Gunvant
openalex +1 more source
Does Rebound Tonometry Probe Misalignment Modify Intraocular Pressure Measurements in Human Eyes?
Purpose. To examine the influence of positional misalignments on intraocular pressure (IOP) measurement with a rebound tonometer. Methods. Using the iCare rebound tonometer, IOP readings were taken from the right eye of 36 healthy subjects at the central
Ian G. Beasley+5 more
doaj +1 more source