Intraocular Pressure Accuracy Post-Myopic Laser in situ Keratomileusis: Pivotal Study Results, Standard vs Correcting Applanation Tonometry Surface Goldmann Tonometry. [PDF]
Kilgore KP, McCafferty S, Levine J.
europepmc +1 more source
Comparison of correction formulas for intraocular pressure measured by Goldmann tonometer following various refractive surgeries (FS-LASIK, SMILE, tPRK). [PDF]
Tong J +15 more
europepmc +1 more source
Challenges in Glaucoma Management in High Myopia After Refractive Surgery: A Case Report. [PDF]
Brazuna R +4 more
europepmc +1 more source
Tomographic and biomechanical corneal characteristics of patients with angioid streaks. [PDF]
Gürelik G +4 more
europepmc +1 more source
Related searches:
Goldmann Applanation Tonometry Free of the Slitlamp
Archives of Ophthalmology, 2010A prototype device was developed for using the Goldmann applanation tonometer (GAT) without a slitlamp to make it potentially practical to measure intraocular pressure (IOP) away from the clinic. Inexpensive consumer video components and a small flashlight replaced the microscope and illuminator of the slitlamp in a device that was assembled to use a ...
Bruce E, Cohan +3 more
openaire +2 more sources
Goldmann Applanation Tonometry without Fluorescein
Optometry and Vision Science, 1981Abstract Recently, there have been several suggestions that Goldmann applanation tonometry can be performed without fluorescein. In order to determine the clinical efficacy of performing Goldmann applanation tonometry without fluorescein, 100 consecutive patients had applanation tonometry performed without fluorescein (Ophthetic only)
D C, Bright +3 more
openaire +2 more sources
Comparison of Proview phosphene tonometry with Goldmann applanation tonometry
Canadian Journal of Ophthalmology, 2006To compare intraocular pressures obtained using a handheld pressure phosphene tonometer (PPT) (Proview, Bausch & Lomb Pharmaceuticals, Inc., Tampa, Fla.) with Goldmann applanation tonometry.Comparative case series of 30 randomly selected patients.The readings obtained with the pressure phosphene tonometer display a higher mean and a larger standard ...
Scott J, Morledge-Hampton +4 more
openaire +2 more sources
Multiparameter Correction Equation for Goldmann Applanation Tonometry
Optometry and Vision Science, 2011ABSTRACT Purpose. To develop a correction factor to improve the accuracy of intraocular pressure (IOP) measurements made by the Goldmann applanation tonometer (GAT), which considers the combined effects of variations in central corneal thickness (CCT), central anterior curvature (R), age, and ...
Ahmed, Elsheikh +3 more
openaire +2 more sources
Comparison of Dynamic Contour Tonometry and Goldmann Applanation Tonometry in Keratoconus
Cornea, 2011We performed a comparative study using Goldmann applanation tonometry (GAT) and dynamic contour tonometry (DCT) to measure intraocular pressure (IOP) in eyes with keratoconus.IOP was measured in 114 eyes of 75 patients with keratoconus (51 men and 24 women; mean age, 36.1 ± 11.2 years) using GAT and DCT in randomized order.
Jan Darius, Unterlauft +4 more
openaire +2 more sources