ABSTRACT Objective To determine the accuracy of the EYEMATE‐SC suprachoroidal tracer for telemetric tonometry in canine and equine globes. Procedures The EYEMATE‐SC sensor (7.8 mm × 3.8 mm × 1 mm) was implanted in the suprachoroidal space of four freshly enucleated normal canine and two normal equine eyes.
Phillip N. Buckman +3 more
wiley +1 more source
Coupled Biomechanical Response of the Cornea Assessed by Non-Contact Tonometry. A Simulation Study [PDF]
The mechanical response of the cornea subjected to a non-contact air-jet tonometry diagnostic test represents an interplay between its geometry, the corneal material behavior and the loading.
Ariza-Gracia, Miguel Á. +4 more
core +6 more sources
Kelechi C Ogbuehi, John C Chijuka, Uchechukwu L Osuagwu Department of Optometry & Vision Science, College of Applied Medical Sciences, King Saud University, Riyadh, Kingdom of Saudi ArabiaBackground: The purpose of this study was to evaluate the ...
Ogbuehi KC, Chijuka JC, Osuagwu UL
doaj
Pressure-Induced Stromal Keratopathy after Surface Ablation Surgery
Introduction: The purpose of this clinical report was to describe an unprecedented case of bilateral pressure-induced stromal keratopathy (PISK) following corneal photorefractive keratectomy, associated with presumed herpetic keratitis, and to present ...
Jaime Guedes +7 more
doaj +1 more source
Abstract Purpose To evaluate the effect of artificial tear (AT) application on the repeatability of corneal parameters with three different devices. Methods In this prospective, randomized clinical trial, 145 patients were measured with one of three devices in the Department of Ophthalmology, Goethe University, Frankfurt, Germany.
Titus Schug +3 more
wiley +1 more source
Reproducibility and clinical relevance of the ocular response analyzer in nonoperated eyes: corneal biomechanical and tonometric implications [PDF]
To assess the reproducibility of the ocular response analyzer (ORA) in nonoperated eyes and the impact of corneal biomechanical properties on intraocular pressure (IOP) measurements in normal and glaucomatous eyes.
Garcia, N. (Noelia) +5 more
core +1 more source
Qasim K FarhoodDepartment of Ophthalmology, College of Medicine, University of Babylon, Babylon, IraqPurpose: Tonometry, or measurement of intraocular pressure (IOP), is one of the most important examination procedures in ophthalmic clinics, and IOP is ...
Farhood QK
doaj
Long‐Term Morphological Changes of Crosslinked Gelatin Stent
ABSTRACT Background This study investigates the long‐term morphological outcomes of crosslinked gelatin stents over a 10‐year period. Methods Participants from the FDA phase 1 and 2 trials for the XEN 140 stent were recalled for follow‐up examinations between 9 and 12 years after their initial implantation.
Yuen Keat Gan +3 more
wiley +1 more source
Purpose Compare intraocular pressure (IOP) measured by a standard Goldmann applanation tonometer prism (IOPg) and a modified correcting applanation tonometer surface Goldmann prism (IOPc) before and after laser in situ keratomileusis (LASIK) and ...
Robert Edward T. Ang +3 more
doaj +1 more source
ABSTRACT Background High myopia (HM) is a major risk factor for glaucoma. However, glaucomatous optic neuropathy is often undiagnosed owing to atypical structural alterations with axial elongation. Moreover, an algorithm to detect glaucoma in highly myopic eyes has not yet been reported.
Xiaohong Chen +14 more
wiley +1 more source