Results 91 to 100 of about 11,431 (187)

A proposed simple method for measurement in the anterior chamber angle: biometric gonioscopy

open access: yes, 1999
OBJECTIVE: To design a system of gonioscopy that will allow greater interobserver reliability and more clearly defined screening cutoffs for angle closure than current systems while being simple to teach and technologically appropriate for use in rural ...

core   +2 more sources

Estudio de la efectividad de la iridoplastia periférica con Nd YAG láser doblado mediante imágenes de Scheimpflug y gonioscopia Study of the effectiveness of double-frequency Nd YAG laser peripheral iridoplasty using Scheimpflug images and gonioscopy

open access: yesRevista Cubana de Oftalmología, 2012
Objetivo: evaluar la efectividad de la iridoplastia periférica con Nd YAG láser doblado mediante imágenes de Scheimpflug y gonioscopia. Métodos: estudio longitudinal descriptivo prospectivo en 40 ojos (23 pacientes) con cierre angular residual (grado 0-2
Liamet Fernández Argones   +5 more
doaj  

Evaluation of a glaucoma patient

open access: yesIndian Journal of Ophthalmology, 2011
The diagnosis of glaucoma is usually made clinically and requires a comprehensive eye examination, including slit lamp, applanation tonometry, gonioscopy and dilated stereoscopic evaluation of the optic disc and retina. Automated perimetry is obtained if
Thomas Ravi, Loibl Klaus, Parikh Rajul
doaj  

Gonioscopy versus anterior segment ocular coherence tomography for anterior chamber angle assessment- A comparative study

open access: yesLiaquat Medical Research Journal
This study was conducted to determine the anterior chamber angle to improve the diagnostic accuracy, treatment modalities and health outcomes in individuals with angle-closure glaucoma.
Ghulam Mujtaba Sohu   +5 more
doaj  

Anterior chamber angle evaluation by ultrasound biomicroscopy and gonioscopy in primary angle closure disease. [PDF]

open access: yes, 2011
AIMS AND OBJECTIVES OF THE STUDY To correlate the angle width measurements by Ultrasound biomicroscopy with gonioscopy. To evaluate the changes in the anterior segment morphology in terms of biometric parameters following laser iridotomy.
Jeevitha, J
core  

Discussion on Gonioscopy [PDF]

open access: yesProceedings of the Royal Society of Medicine, 1950
openaire   +2 more sources

Degrees of posterior trabecular meshwork not visible and peripheral anterior synechiae at baseline and 1 month after cataract extraction (N = 26 eyes)1 by gonioscopy.

open access: yes, 2016
Degrees of posterior trabecular meshwork not visible and peripheral anterior synechiae at baseline and 1 month after cataract extraction (N = 26 eyes)1 by gonioscopy.
Jeffrey R. Peterson (1349334)   +6 more
core   +1 more source

Comparing the effect of sympathomimetic/anticholinergic psychotropic drugs with that of non-sympathomimetic/anticholinergic psychotropic drugs on IOP and angle parameters among patients on long-term therapy

open access: yesIndian Journal of Ophthalmology
Purpose: The purpose of this study was to compare the effect of sympathomimetic or anticholinergic psychotropic drugs (tricyclic antidepressants, selective serotonin reuptake inhibitors, and benzodiazepines (TCADs, SSRIs, and BZDs)) with that of non ...
Geeta Behera   +8 more
doaj   +1 more source

Malignant glaucoma – A rare complication following gonioscopy-assisted transluminal trabeculotomy

open access: yes
A patient with primary angle-closure glaucoma developed malignant glaucoma 2 weeks after combined gonioscopy-assisted transluminal trabeculotomy with phacoemulsification.
Ramarghya K Chakraborty   +5 more
core   +1 more source

Novel hyperparallel optical coherence tomography for angle closure assessment: Comparison with swept-source OCT and gonioscopy

open access: yes
Aim To evaluate reproducibility and agreement of angle closure assessment by a novel hyperparallel optical coherence tomography (OCT) system (HP-OCT, Cylite Optics, Melbourne, Australia), in comparison with swept-source OCT (SS-OCT, CASIA SS-1000, Tomey ...
Tan, Bingyao   +10 more
core   +1 more source