Results 1 to 10 of about 22,594 (217)

Vulnerability and Impact Analysis of the IEC 61850 GOOSE Protocol in the Smart Grid [PDF]

open access: goldSensors, 2021
IEC 61850 is one of the most prominent communication standards adopted by the smart grid community due to its high scalability, multi-vendor interoperability, and support for several input/output devices. Generic Object-Oriented Substation Events (GOOSE),
Haftu Tasew Reda   +6 more
doaj   +10 more sources

Development of 3-phase fault detection, protection, and automation application with the present of DG in AC power system using GOOSE protocol [PDF]

open access: goldHeliyon
In this research work, a protection and automation solution is developed, encompassing SEL751 and SEL751A protection relays that communicate through the IEC-61850 Generic Object-Oriented Substation Event (GOOSE) protocol to deliver high-speed detection ...
Zhongsheng Shi, Zumrat Druzhinin
doaj   +8 more sources

Substation digitalisation via GOOSE protocol between intelligent electronic devices

open access: diamondInformatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska
The article addresses the implementation of projects for new digital substations, as well as upgrading existing substations using digital intelligent electronic devices.
Laura Yesmakhanova   +3 more
doaj   +4 more sources

Applying domain-specific knowledge to construct features for detecting distributed denial-of-service attacks on the GOOSE and MMS protocols [PDF]

open access: greenInternational Journal of Critical Infrastructure Protection, 2018
Abstract Electric substation automation systems based on the IEC 61850 standard predominantly employ the GOOSE and MMS protocols. Because GOOSE and MMS messages are not encrypted, an attacker can observe packet header information in protocol messages and inject large numbers of spoofed messages that can flood a substation automation system ...
Ernest Foo
exaly   +5 more sources

Adapting LTE M-2-M Protocol Standard to Fulfil Latency Requirements for IEC 61850 GOOSE Messages

open access: diamondInternational Journal of Communications, Network and System Sciences, 2015
Generic Object Oriented Substation Event (GOOSE) Messages face a great challenge in its communication requirements especially in latency point of view. The appearance of the Long-Term Evolution (LTE) has opened a new way that can be used due to its great performance, compared with previous wireless technologies.
Ali M. Allam, Mohamed Saied, Ihab Aly
exaly   +4 more sources

Development of Intrusion Detection System for GOOSE Protocol Based on the Snort

open access: bronzeJournal of the Korea Institute of Information Security and Cryptology, 2013
Hyeong-Dong Kim   +2 more
exaly   +4 more sources

A Method for Mining GOOSE Protocol Parsing Vulnerabilities Based on Fuzzing

open access: yesZhongguo dianli, 2022
The existing fuzzing methods for industrial control protocol do not consider the characteristics of the embedded terminal systems, and have few research on the industrial control protocol without TCP/IP. Firstly, a fuzzing-based method for mining generic
Linbin LIU, Quanqiang MIAO, June LI
doaj   +2 more sources

Masquerading IEC 61850 GOOSE Protocol: Cyber‐Physical Experiments and Detection [PDF]

open access: goldProceedings of the 16th ACM International Conference on Future and Sustainable Energy Systems
In a Hardware-in-the-Loop digital substation, we show that a network attacker can spoof a GOOSE trip to open a breaker. We propose two detectors—one machine-learning, one rule-based—and illustrate both attack and defense in an interactive demo for awareness.
Hermenegildo da Conceição Alberto   +5 more
openaire   +2 more sources

Testing of Goose Protocol of IEC61850 Standard in Protection IED

open access: bronzeInternational Journal of Computer Applications, 2014
High speed communication between IED to IED is required for successful implementation of protection schemes in a substation automation system. IEC 61850 is an International standard that supports high speed peer-to-peer services like GOOSE. The communication using GOOSE protocol replaces point to point copper wiring between the IEDs in conventional ...
Jignesh Gohil   +2 more
openaire   +2 more sources

A Protocol for Producing Quality Control Materials for Hematology Testing Using Porcine and Goose Blood v2 [PDF]

open access: gold
Commercial hematology internal quality control (IQC) materials are often costly, imported, and have limited shelf life, which poses a significant challenge for laboratories in low- and middle-income countries (LMICs). This protocol presents a low-cost, locally adaptable method for preparing IQC materials targeting white blood cell (WBC) parameters ...
N.N. Vo   +6 more
  +5 more sources

Home - About - Disclaimer - Privacy