Results 161 to 170 of about 6,907 (287)

Effect of build orientation on the fabrication trueness of additively manufactured implant‐supported complete arch interim fixed prostheses

open access: yesJournal of Prosthodontics, EarlyView.
Abstract Purpose To evaluate how build orientation affects the fabrication trueness of additively manufactured implant‐supported complete arch prostheses by comparing them to subtractively manufactured high‐impact polymer‐based prostheses. Materials and Methods An edentulous maxillary model with four implants at canine and first molar regions ...
Amir H. Nejat   +4 more
wiley   +1 more source

Wettability of saliva substitutes across various denture base fabrication techniques

open access: yesJournal of Prosthodontics, EarlyView.
Abstract Purpose The present study evaluated the contact angles (CAs) of four denture base materials subjected to different surface treatments using deionized water and saliva substitutes. Material and Methods A total of 32 rectangular specimens were manufactured using four different denture base materials: heat‐cured compression molded Lucitone 199 (C)
Paul Mikhail   +3 more
wiley   +1 more source

Effects of autoclave sterilization on the dimensional stability of implant surgical guides: A 3D in vitro analysis

open access: yesJournal of Prosthodontics, EarlyView.
Abstract Purpose Surgical guides are medical devices used in static implant surgery to replicate the prosthetic and surgical implant position planned with computer‐assisted software before surgery. Their use reduces invasiveness and improves safety and outcomes of implant surgery, provided that their accuracy is ensured from design to manufacturing and
Lucio Lo Russo   +6 more
wiley   +1 more source

Marginal gap of printed, milled, and heat‐pressed two‐piece polyetheretherketone abutments before and after thermal cycling, and their pull‐off bond strength after thermal cycling

open access: yesJournal of Prosthodontics, EarlyView.
Abstract Purpose To evaluate the marginal gap of two‐piece polyetheretherketone (PEEK) abutments fabricated with different methods, before and after thermal cycling, while also focusing on their pull‐off bond strength. Materials and Methods A two‐piece abutment was virtually designed after digitizing a titanium‐base (Ti‐base) abutment.
Almira Ada Diken Türksayar   +6 more
wiley   +1 more source

Workflow to facilitate complete denture scanning with an intraoral scanner: A technique report

open access: yesJournal of Prosthodontics, EarlyView.
Abstract Scanning a denture with an intraoral scanner is typically more challenging than scanning a dentate arch. This article describes a novel technique for digitally duplicating a complete denture. The workflow involves scanning an existing denture using an intraoral scanner with the addition of specific markers and subsequently constructing a ...
Jiayi Yu   +3 more
wiley   +1 more source

Home - About - Disclaimer - Privacy