Results 91 to 100 of about 1,936,556 (294)

Microfluidic Nano‐Assembly of Red‐Blood‐Cell (RBC) Lipids and Components for Engineering Extracellular Vesicles

open access: yesAdvanced Healthcare Materials, EarlyView.
Engineered red blood cell‐derived extracellular vesicles (eRBCEVs) are synthesized via controlled microfluidic assembly from native RBC lipids, enabling tunable encapsulation of proteins, nucleic acids, nanoparticles, and viral vectors. The platform demonstrates reproducible nanoscale architecture, preserved membrane composition, and functional cargo ...
Chiranth K. Nagaraj   +23 more
wiley   +1 more source

Low Voltage Ride-Through Capability of Grid-Connected PV Systems: A Comparative Study of Grid-Following and Grid-Forming Converters Under Current Limits

open access: yesIEEE Access
This study investigates the Low Voltage Ride-Through (LVRT) capabilities of grid-connected photovoltaic (PV) systems, focusing on the comparative performance of Grid-Following (GFL) and Grid-Forming (GFM) converters under current limit constraints.
Zainab M. Almesri   +2 more
doaj   +1 more source

NeuroVisio SyncPatch: A Skin‐Conformal Multimodal EMG–Motion Sensing Platform for Quantitative Neuromuscular Rehabilitation and Performance Monitoring

open access: yesAdvanced Healthcare Materials, EarlyView.
NeuroVisio SyncPatch integrates skin‐conformal electromyography (EMG) electrodes with camera‐tracked markers to jointly assess muscle activity and three‐dimensional knee kinematics during rehabilitation. Parallel feedback pathways provide real‐time kinematic guidance during movement and post‐trial neuromuscular feedback.
Bohyung Choi   +11 more
wiley   +1 more source

Rational Control of Antibody Orientation for Enhancing Sensitivity and Specificity in Lateral Flow Immunoassays With Clinical Validation

open access: yesAdvanced Healthcare Materials, EarlyView.
Systematic investigation of antibody orientation strategies in lateral flow immunoassays reveals that a para‐substituted (aminomethyl)phenylboronic acid mediated probe (P‐6) combined with a biotin‐streptavidin test‐line modification achieves a synergistic 14‐ to 19‐fold sensitivity gain over conventional conjugation. Furthermore, multiplexed detection,
Pin‐Hao Wang   +5 more
wiley   +1 more source

Atom‐Efficient Cerium‐Based Molecular Cages as Biocompatible Reactive Oxygen Scavengers

open access: yesAdvanced Healthcare Materials, EarlyView.
Discrete mixed‐valent cerium molecular cages organize accessible redox centers within confined coordination environments and scavenge superoxide, hydrogen peroxide, and hydroxyl radicals. Encapsulation of the lead cage in an ROS‐responsive DTP nanoplatform enables lesion‐associated delivery, attenuates macrophage oxidative stress and inflammation, and ...
Chao Li   +9 more
wiley   +1 more source

Ferroelectric Quantum Dots for Retinomorphic In‐Sensor Computing

open access: yesAdvanced Materials, EarlyView.
This work has provided a protocol for fabricating retinomorphic phototransistors by integrating ferroelectric ligands with quantum dots. The resulting device combines ferroelectricity, optical responsiveness, and low‐power operation to enable adaptive signal amplification and high recognition accuracy under low‐light conditions, while supporting ...
Tingyu Long   +26 more
wiley   +1 more source

Robust mixed H2/ H∞ based optimal controller design for single-phase grid-connected converter

open access: yes, 2016
In order to integrate more and more renewable energy resources to the main grid, single-phase grid-connected converters (GCCs) have gained more attention.
Li ZW(李忠文)   +6 more
core  

Wind Turbine Driving a PM Synchronous Generator Using Novel Recurrent Chebyshev Neural Network Control with the Ideal Learning Rate

open access: yesEnergies, 2016
A permanent magnet (PM) synchronous generator system driven by wind turbine (WT), connected with smart grid via AC-DC converter and DC-AC converter, are controlled by the novel recurrent Chebyshev neural network (NN) and amended particle swarm ...
Chih-Hong Lin
doaj   +1 more source

n‐Type Polymer Radio Frequency Rectifiers Operating at 18.5 GHz

open access: yesAdvanced Materials, EarlyView.
Combining an n‐doped polymer semiconductor with wafer‐scale asymmetric planar electrodes featuring work function‐engineered contacts yields radio‐frequency diodes and rectifying circuits operating at up to 18.5 GHz. The devices combine scalable manufacturing with an operating frequency previously unattainable by large‐area organic electronics ...
Lazaros Panagiotidis   +19 more
wiley   +1 more source

Pulse-width-modulation-based electromagnetic interference mitigation of bidirectional grid-connected converters for electric vehicles

open access: yes, 2017
This paper proposes a new pulse-width-modulation (PWM) technique for the electromagnetic interference (EMI) mitigation of the bidirectional grid-connected converter, which is aiming to improve the power quality of power grids and the working environment ...
Chau, KT, Zhang, Z
core   +1 more source

Home - About - Disclaimer - Privacy