Results 101 to 110 of about 1,827,778 (298)
A three-phase three-wire LCL grid-connected inverter is usually used as an interface between renewable-energy sources and grid. However, grid voltage is always distorted and results in grid-current distortion when there is no control at the filter ...
Tsai-Fu Wu +5 more
doaj +1 more source
DC to AC inverters are the well-known and improved in various kinds photovoltaic (PV) and gird tied systems. However, these inverters are require interfacing transformers to be synchronized with the grid-connected system.
P. Madasamy +5 more
doaj +1 more source
Optically pumped magnetometers are employed to contactlessly map the spatiotemporal dynamics of the magnetic field linked to electrical activity of a skeletal muscle in vivo. It is demonstrated that localization of the clinically relevant innervation zone is feasible using this non‐invasive magnetic measurement modality. ABSTRACT Magnetomyography (MMG)
Simon Nordenström +12 more
wiley +1 more source
Microgrid power electronic converters: state of the art and future challenges
This paper presents a review of the state of the art of power electric converters used in microgrids. The paper focuses primarily on grid connected converters.
Sharkh, S.M. +4 more
core +1 more source
Flexible Sensors for Robotics Tactile Perception: A Review
Flexible tactile sensing for robotics is reviewed through four interconnected dimensions. Physical mechanisms include piezoresistive, capacitive, piezoelectric, triboelectric, iontronic, and optical sensing. Structural design includes bioinspired, defect‐based, and MEMS‐based tactile systems.
Yu Song, Ying Chen, Yihao Chen, Xue Feng
wiley +1 more source
Parameter identification of PLL for grid‐connected inverter based on parameter sensitivity analysis
Under the condition of weak grid, the phase‐locked loop (PLL) is one of the main reasons for the sub‐synchronous oscillation of the grid‐connected inverter.
Fei Li +6 more
doaj +1 more source
Compared to the traditional thermal power generation, new energy sources, such as wind and photovoltaic systems, are more vulnerable to the effects of non-ideal power grids due to their limited capacity.
Xianwen Bao, Lirong Zhang
doaj +1 more source
A Control Strategy of a Single-phase H6-type Grid-connected Inverter with Low Harmonic Current
In order to reduce the total harmonic distortion (THD) of the grid-connected current caused by the high-frequency switching of the inverter, this paper combines the high efficiency single-phase H6-type inverter with LCL filter.
Chunxu Lin +3 more
doaj +1 more source
Grid-connected inverter fault diagnosis in closed loop
At present, the fault diagnosis method for the grid-connected inverter is mainly applied to the open-loop system, and the actual grid-connected inverter is mostly a closed-loop control system. Therefore, for the grid-connected inverter in the closed-loop
Han Yan, Pazilai Mahemuti
doaj +1 more source
A High-Gain and High-Efficiency Photovoltaic Grid-Connected Inverter with Magnetic Coupling. [PDF]
Chang CH, Cheng CA, Cheng HL, Chang EC.
europepmc +1 more source