Results 101 to 110 of about 1,827,778 (298)

Grid-Side Current Improvement With Direct Digital Control and Capacitor Voltage Feedforward to Mitigate Distorted Grid Currents for 3Φ3W LCL Grid-Connected Inverter Under Distorted Grid Voltages

open access: yesIEEE Open Journal of Power Electronics
A three-phase three-wire LCL grid-connected inverter is usually used as an interface between renewable-energy sources and grid. However, grid voltage is always distorted and results in grid-current distortion when there is no control at the filter ...
Tsai-Fu Wu   +5 more
doaj   +1 more source

A Three-Phase Transformerless T-Type- NPC-MLI for Grid Connected PV Systems with Common-Mode Leakage Current Mitigation

open access: yesEnergies, 2019
DC to AC inverters are the well-known and improved in various kinds photovoltaic (PV) and gird tied systems. However, these inverters are require interfacing transformers to be synchronized with the grid-connected system.
P. Madasamy   +5 more
doaj   +1 more source

High‐Density Magnetomyography With Optical Magnetometers Reveals Spatiotemporal Patterns of Evoked Muscle Activity

open access: yesAdvanced Materials Technologies, EarlyView.
Optically pumped magnetometers are employed to contactlessly map the spatiotemporal dynamics of the magnetic field linked to electrical activity of a skeletal muscle in vivo. It is demonstrated that localization of the clinically relevant innervation zone is feasible using this non‐invasive magnetic measurement modality. ABSTRACT Magnetomyography (MMG)
Simon Nordenström   +12 more
wiley   +1 more source

Microgrid power electronic converters: state of the art and future challenges

open access: yes, 2009
This paper presents a review of the state of the art of power electric converters used in microgrids. The paper focuses primarily on grid connected converters.
Sharkh, S.M.   +4 more
core   +1 more source

Flexible Sensors for Robotics Tactile Perception: A Review

open access: yesAdvanced Robotics Research, EarlyView.
Flexible tactile sensing for robotics is reviewed through four interconnected dimensions. Physical mechanisms include piezoresistive, capacitive, piezoelectric, triboelectric, iontronic, and optical sensing. Structural design includes bioinspired, defect‐based, and MEMS‐based tactile systems.
Yu Song, Ying Chen, Yihao Chen, Xue Feng
wiley   +1 more source

Parameter identification of PLL for grid‐connected inverter based on parameter sensitivity analysis

open access: yesIET Power Electronics
Under the condition of weak grid, the phase‐locked loop (PLL) is one of the main reasons for the sub‐synchronous oscillation of the grid‐connected inverter.
Fei Li   +6 more
doaj   +1 more source

Enhancing grid-connected inverter performance under non-ideal grid conditions: a multi-functional multiplexing control strategy

open access: yesFrontiers in Energy Research
Compared to the traditional thermal power generation, new energy sources, such as wind and photovoltaic systems, are more vulnerable to the effects of non-ideal power grids due to their limited capacity.
Xianwen Bao, Lirong Zhang
doaj   +1 more source

A Control Strategy of a Single-phase H6-type Grid-connected Inverter with Low Harmonic Current

open access: yesMATEC Web of Conferences, 2018
In order to reduce the total harmonic distortion (THD) of the grid-connected current caused by the high-frequency switching of the inverter, this paper combines the high efficiency single-phase H6-type inverter with LCL filter.
Chunxu Lin   +3 more
doaj   +1 more source

Grid-connected inverter fault diagnosis in closed loop

open access: yesDianzi Jishu Yingyong, 2019
At present, the fault diagnosis method for the grid-connected inverter is mainly applied to the open-loop system, and the actual grid-connected inverter is mostly a closed-loop control system. Therefore, for the grid-connected inverter in the closed-loop
Han Yan, Pazilai Mahemuti
doaj   +1 more source

Home - About - Disclaimer - Privacy