Results 11 to 20 of about 1,761,219 (294)
An Optimal Current Controller Design for a Grid Connected Inverter to Improve Power Quality and Test Commercial PV Inverters [PDF]
Grid connected inverters play a crucial role in generating energy to be fed to the grid. A filter is commonly used to suppress the switching frequency harmonics produced by the inverter, this being passive, and either an L- or LCL-filter.
Ali Algaddafi +3 more
doaj +2 more sources
Grid frequency support from inverter connected generation [PDF]
This paper presents a case study to demonstrate impact of current fleet of inverter connected generation (roof top photovoltaics and utility scale grid following inverters) that have been allowed to connect to power networks with no obligations to ...
Ahfock, Tony +6 more
core +1 more source
Robust repetitive feedback control of a three-phase grid connected inverter [PDF]
This paper discusses the design of a repetitive feedback controller for a grid-connected two-level three-phase voltagesource inverter connected between a DC source and the grid through an LCL filter.
Sharkh, S.M. +8 more
core +2 more sources
Current sourcing isolated grid connected inverter [PDF]
This study proposes a soft switched Output Current Sourcing (OCS) grid connected inverter that applies a high frequency isolation transformer. Current sourcing at the output implies that, ideally, the injected current will be independent of the load voltage.
Ilya Zeltser, Sam Ben-Yaakov
openaire +2 more sources
Tradeoffs between AC power quality and DC bus ripple for 3-phase 3-wire inverter-connected devices within microgrids [PDF]
Visions of future power systems contain high penetrations of inverters which are used to convert power from dc (direct current) to ac (alternating current) or vice versa.
Finney, Stephen J. +2 more
core +4 more sources
Grid impedance variation and voltage harmonics may cause instability of the grid-connected inverter system and reduce the grid current quality under weak grid.
Liyong Yang +3 more
doaj +1 more source
Integrated PV and multilevel converter system for maximum power generation under partial shading conditions [PDF]
The emerging trend towards the harnessing of the electrical power from solar energy has increased the research effort in power electronics applications.
Abdalla, Imadeddin Abdalla
core +6 more sources
Small-signal stability problems often occur when the inverter for renewable energy generation is connected to weak grid. A small-signal transfer function integrated model reflecting the interaction of grid impedance, phase locked-loop (PLL), and current ...
Zhiwei Xie +6 more
doaj +1 more source
New energy power generation devices are mostly located in weak power grid areas, where the grid voltage harmonic content is high. Affected by the grid voltage harmonics and switching characteristics, the current of the grid-connected inverter is prone to
TIAN Yuansong +3 more
doaj +1 more source
A fully decentralized control of grid-connected cascaded inverters [PDF]
2 Pages, 2 ...
Xiaochao Hou +5 more
openaire +2 more sources

