Results 221 to 230 of about 2,165 (267)
Some of the next articles are maybe not open access.

Fault contribution of grid-connected inverters

2009 IEEE Electrical Power & Energy Conference (EPEC), 2009
The distribution grid is mainly built on a radial configuration where power is coming from one transformer substation to supply clients. Up to recently, in the rare cases where distributed generation existed, it was almost exclusively constituted of rotating machines, which have quite a different behaviour under fault than inverter-based sources ...
Dave Turcotte, Farid Katiraei
openaire   +1 more source

Enhanced utilization of grid-connected inverter

2015 IEEE 6th International Symposium on Power Electronics for Distributed Generation Systems (PEDG), 2015
Smooth mode transfer of voltage source inverter (VSI) between grid-connected and stand-alone modes is achieved by operating the inverter in voltage control mode (VCM). However, this operation produces some adverse practical issues such as requirement of large rating VSI, limited real power injection by VSI, negligible operational capability in strong ...
Chandan Kumar   +2 more
openaire   +1 more source

Design of a Seamless Grid-Connected Inverter for Microgrid Applications

IEEE Transactions on Smart Grid, 2020
The objective of this paper is to propose a seamless grid-connected inverter (SGI) for microgrid applications. The proposed SGI is able to operate in the grid-connected mode or the standalone mode. In order to smooth the transfer transition from the grid-connected mode to the standalone mode and to isolate the microgrid from the grid fault immediately ...
Kuo-Yuan Lo, Yaow-Ming Chen
openaire   +1 more source

Novel grid-connected photovoltaic inverter

IEE Proceedings - Generation, Transmission and Distribution, 1996
Detailed analysis and simulation results of a novel solar photovoltaic inverter configuration interconnected to the grid are presented. From the simulation results it is confirmed that the harmonic distortion of the output current waveform of the inverter fed to the grid is within the stipulated limits laid down by the utility companies.
SAHA, S, SUNDARSINGH, VP
openaire   +2 more sources

A grid connected current source inverter.

2009 International Conference on Clean Electrical Power, 2009
In Co-generation systems are required converters able to inject current with low harmonic content, traditionally the inverters are considered. In this paper is proposed to use the current source inverter instead of voltage source inverter, this type of inverters can accept a low input voltage to inject current to the ac mains. The operation, simulation
N. Vazquez   +5 more
openaire   +1 more source

Dynamics of grid connected PV inverters

2010 IEEE International Energy Conference, 2010
Power failure of electric network identifies the hazardous aspects of inverter grid interfacing to linesmen maintaining power lines. Dynamics of grid-connected first order system indicates the necessity for an optimum tripping mechanism for an inverter feeding diversity of locally connected loads are analysed.
Khalid Hasan Masoud, Gerard Ledwich
openaire   +1 more source

Droop PLL for grid-connected inverter

Proceedings of The 7th International Power Electronics and Motion Control Conference, 2012
Using grid voltage feed-forward control, the current-loop parameters and filter inductor affect the power factor of grid-connected inverter. Based on droop phase-locked loop (PLL) a novel control strategy is proposed. The phase difference between the grid current and grid voltage is detected and is used to calculate the output frequency of PLL.
null Jia-rong Kan   +4 more
openaire   +1 more source

A single-phase grid-connected PV inverter with improved grid-connected current

The 27th Chinese Control and Decision Conference (2015 CCDC), 2015
This paper presents an effective method, which can address the existing dc-link double-line-frequency voltage ripples in single-phase grid-connected PV inverters, to improve the grid-connected current. The instantaneous power pulsations at grid side cause double-line-frequency fluctuations of the dc-link voltage in single-phase grid-connected PV ...
Furong Xiao, Lei Dong, Xiaozhong Liao
openaire   +1 more source

Two-stage grid-connected inverter for PV systems

2018 IEEE 12th International Conference on Compatibility, Power Electronics and Power Engineering (CPE-POWERENG 2018), 2018
In this study, a two-stage grid-connected inverter is proposed for photovoltaic (PV) systems. The proposed system consist of a single-ended primary-inductor converter (SEPIC) converter which tracks the maximum power point of the PV system and a three-phase voltage source inverter (VSI) with LCL filter to export the PV supplied energy to the grid.
Altin, Necmi   +4 more
openaire   +2 more sources

The Application of SiC Devices in Photovoltaic Grid-connected Inverters

Proceedings of the 2nd International Conference on Artificial Intelligence and Advanced Manufacture, 2020
The continuous development of photovoltaic grid-connected technology extended the requirement on higher power density and higher efficiency for power converters. In this respect, the application of silicon carbide (SiC) high-power power electronic devices in photovoltaic inverter systems can simplify the system design, simplify the heat dissipation ...
Yongping Li   +8 more
openaire   +1 more source