Results 41 to 50 of about 3,545,681 (293)
Ground Coupled Heat Pump Design for Tafila Climate [PDF]
This work represents a theoretical investigation of a ground coupled heat pump system that is used for domestic heating and cooling purposes of a typical residential house in Tafilah-Jordan.
Emran. M. Ataykah
doaj +1 more source
Thermal efficiency of geothermal ventilation under conditions of temperate climate
The article deals with modern energy-efficient systems for providing the microclimate of energy-saving buildings, consisting of geothermal ventilation with ground heat exchangers. The results of modern scientific research in this field are described.
Vasyl Zhelykh
doaj +1 more source
A derivative method for minimising total cost in heat exchanger networks through optimal area allocation [PDF]
This paper presents a novel Cost Derivative Method (CDM) for finding the optimal area allocation for a defined Heat Exchanger Network (HEN) structure and stream data, without any stream splits to achieve minimum total cost. Using the Pinch Design Method (
Walmsley, Michael R.W. +4 more
core +2 more sources
Heat Transfer Modeling of the Ground Heat Exchangers for the Ground-Coupled Heat Pump Systems [PDF]
None
Yi Man, Ping Cui, Zhaohong Fang
openaire +2 more sources
Thermal Response of Helix Ground Heat Exchangers [PDF]
This paper is devoted to the thermal analysis of shallow ground heat exchangers with pipes arranged in a helix configuration. The pipes where the carrier fluid is circulated typically embrace a cylindrical volume that is filled by ground or concrete, the
Priarone, Antonella +7 more
core +1 more source
We present robust protocols for the preparation of supported lipid bilayers (SLBs) incorporating either Salmonella smooth LPS or outer membrane vesicles (OMVs). We use a combination of quartz crystal microbalance with dissipation (QCM‐D) and fluorescence microscopy to both characterize the SLBs of various compositions and to probe their interactions ...
Hudson P. Pace +6 more
wiley +1 more source
Fouling of a double pipe heat exchanger [PDF]
Every single heat exchanger in operation in modern industries is exposed to fouling to a greater or lesser extent depending on the surface temperature, surface condition, material of construction, fluid velocity, flow geometry and fluid composition.
Llinares Fontdevila, Antonio
core +1 more source
Optimization of Parameters of a Vertical Ground Heat Exchanger in a Geothermal Heating System
This study presents the results of an original study on the influence of selected parameters on the thermal efficiency of a vertical ground heat exchanger (VGHE) in a ground-source heat pump (GSHP) system.
Walery Jezierski, Piotr Rynkowski
doaj +1 more source
Southeast Asian countries have experienced fast economic growth for several decades. This rapid growth has been accompanied by an increased energy demand per capita. Ground source heat pumps could be a solution to improve energy efficiency.
Arif Widiatmojo +8 more
doaj +1 more source
Methodology for estimating the ground heat absorption rate of Ground Heat Exchangers
Abstract In Ground Source Heat Pump systems, the heat exchange rate is an important factor with regard to the initial cost of the system. When the Ground Heat Exchanger (GHE) is installed in a lithology with high thermal properties in the presence of groundwater, the heat exchange rates are larger than in the cases with poor thermal response of the ...
Stylianou, II +4 more
openaire +3 more sources

