Results 1 to 10 of about 10,909,381 (195)
Due to the impedance characteristic of conductor, the ground potential rise is different within grounding grid when impulse current is injected. When staff touches objects with different GPR at the same time, the GPD will be applied to human body ...
Chun Li +5 more
doaj +2 more sources
Accurate characterization of subsurface electrical behavior during high‐energy fault events is critical for both geotechnical safety assessment and the protection of power infrastructure.
Wulfran Fendzi Mbasso +7 more
doaj +2 more sources
Abydos Temple is one of Egypt’s most significant sites which has a long history that dates back to the ancient monarchy and continued until the coming of Islam and also served as one of Egypt’s most significant ancient royal and high-ranking official ...
Abdelbaset M. Abudeif +3 more
doaj +1 more source
Harmonic grounding impedance of rods in horizontally stratified soils using ABCD-matrix approach
Grounding electrodes play a fundamental role in the operation of power systems. In this context, precise computation of grounding impedance must consider the frequency-dependence of the soil parameters and the ground organized in stratified layers of ...
Anderson R.J. de Araújo +4 more
doaj +1 more source
Improving a tower earthing system by reducing the impedance is an effective solution to prevent back flashover from occurring and thus maintaining the sustainable operation of power supply.
N. Nasir +7 more
semanticscholar +1 more source
Frequency Dependence of Multilayer Soil Electrical Parameters: Effects on Ground Potential Rise
The paper presents a comprehensive study on the effect of frequency dependence of multilayer soil electrical parameters (SEPs) on ground potential rise (GPR). The lightning current has a large effect on the GPR.
M. Ghomi, C. Bak, Filipe Faria da Silva
semanticscholar +1 more source
Ground Potential Rise and Transient Response of the Grounding Grid Based on the Triggered Lightning
It is extremely dangerous of ground grid potentials which significantly rise when the lightning currents are flowing through the grid. A statistical analysis on 39 return-strokes, 10 M-components and the ground potential rise (GPR) caused by them based ...
Yan Xu +4 more
doaj +1 more source
Adequate soil modeling is fundamental to assessing the grounding impedance of the grounding system and the transient responses in power systems. This paper aims to investigate three soil models with electrical parameters varying with frequency and water ...
Walter Luiz Manzi de Azevedo +4 more
doaj +1 more source
Characteristics of Two Ground Grid Potentials After a Triggered Lightning Stroke
It has been determined that the discharge of lightning current to ground through grounding grid results in high potential at the grounding grid and other nearby grounding grids, which is very destructive.
Xu Yan +5 more
doaj +1 more source