Results 71 to 80 of about 22,307,553 (287)

Performance of a hybrid ground source heat pump system with open-loop and closed-loop ground heat exchangers [PDF]

open access: yesE3S Web of Conferences
Ground source heat pump (GSHP) systems have gained attention as high-efficiency heat sources because they utilize relatively stable ground temperatures through ground heat exchangers (GHX).
Choi Minyoung   +4 more
doaj   +1 more source

Preferential Interfacial Engineering of Hydrogels via Interdigitated Nanoparticle Assembly

open access: yesAdvanced Functional Materials, EarlyView.
Robust surface functionalization of hydrogel surfaces is performed via interdigitated metal nanoparticle assembly, inducing strong affinity with the hydrogel matrix. The partially exposed nanoparticle domains act as interfacial nanobridges that mediate both chemical and physical bonding with diverse materials, including small molecules, fluorous ...
Hyeonjin Kim   +11 more
wiley   +1 more source

Anisotropic Phonon Dynamics and Directional Transport in Actinide Van der Waals Semiconductor Uranium Triselenide

open access: yesAdvanced Functional Materials, EarlyView.
USe3 is introduced as an actinide van der Waals semiconductor that mirrors the quasi‐one‐dimensional physics of transition‐metal trichalcogenides. Polarization‐resolved Raman spectroscopy on exfoliated flakes maps strong in‐plane phonon anisotropy and strain‐tunable mode shifts.
Aljoscha Söll   +17 more
wiley   +1 more source

Ground Source Heat Pump in Heating System with Electronics Monitoring

open access: yesJournal of Electrical and Electronics Engineering, 2013
The monitoring system is implemented for a ground coupled heat pump in heating/ system. The borehole heat exchangers – which are 150 m long - are filled with a mixture of water and ethilene glycol calledbrine. Metering and monitoring energy consumption is achieved for: heat pump, circulation pumps, additional electrical heating, hot air ventilation ...
NEAMŢU Ovidiu   +3 more
openaire   +1 more source

Desert Plant Inspired Hierarchical Nanofibrous Membranes for Integrated Solar Desalination and Heavy Metal Remediation

open access: yesAdvanced Functional Materials, EarlyView.
An Alhagi maurorum inspired hierarchical composite membrane (NFCu) was developed by integrating heavy metal remediation and solar‐driven interfacial evaporation in a single platform. Beyond the photothermal effect, a localized photocatalytic process is realized on the CuO surface, deepening the mechanistic understanding of light–matter–water ...
Yuqiong He   +9 more
wiley   +1 more source

Optimal control and operation of a GSHP system for heating and cooling in an office building

open access: yes, 2017
Ground source heat pump (GSHP) systems are widely considered as being among the most efficient heating and cooling renewable technologies currently available. Nevertheless, both an optimal design of components and an optimal operation of the system as a
Corberán, José M.   +7 more
core   +1 more source

Conjugated Porphyrin Polymer With Superior Charge Transfer for Photodynamic‐Immunomodulatory Prevention of CIED Infection in Diabetes

open access: yesAdvanced Healthcare Materials, EarlyView.
Under NIR irradiation, PTCPP generates ROS to eliminate MRSA biofilms and promote M1 macrophage polarization for phagocytosis. After bacterial clearance, the material is phagocytosed by macrophages, shifting their polarization to M2 phenotype via metabolic reprogramming, which synergistically enhances anti‐infection therapy and wound healing.
Honghao Ma   +13 more
wiley   +1 more source

In situ optimization methodology for the water circulation pumps frequency of ground source heat pump systems: Analysis for multistage heat pump units [PDF]

open access: yes, 2015
[EN] In order to optimize the global energy performance of a ground source heat pump system, special attention needs to be paid to the auxiliaries as they stand for a considerable part of the total energy consumption.
Cervera Vázquez, Javier   +2 more
core   +1 more source

GROUND TEMPERATURE MONITORING FOR A COAXIAL GEOTHERMAL HEAT EXCHANGERS FIELD: PRACTICAL ASPECTS AND MAIN ISSUES FROM THE FIRST YEAR OF MEASUREMENTS

open access: yesRudarsko-geološko-naftni Zbornik, 2018
Ground temperature at shallow depth (< 50 m) is not stable, nor in space, neither in time, and its behaviour is the result of superimposition of effects of heat pulses of different origin: solar, geothermal and anthropic. The correct assessment of ground
Francesco Tinti   +6 more
doaj   +1 more source

Mitochondria‐Targeted Nanotherapies in Aging Neurodegenerative Disorders: Emerging Prospects and Clinical Potential

open access: yesAdvanced Healthcare Materials, EarlyView.
Mitochondria‐targeted nanotherapies emerge as a promising strategy for combating aging‐associated neurodegenerative disorders (NDs) by restoring mitochondrial function, reducing oxidative stress, and improving neuronal survival. Recent advances in nanotechnology, therapeutic delivery, and translational research are highlighted, providing insights into ...
Dnyandev G. Gadhave   +8 more
wiley   +1 more source