Results 301 to 310 of about 4,782,069 (378)
Some of the next articles are maybe not open access.

Lightning Strike at a Grounding Device

Elektrichestvo, 2020
The statistical distributions of lightning current parameters obtained from an analysis of natural lightning waveforms carried out by three research centers are considered, and it has been found from the consideration results that the extreme values of these parameters, based on which the recommendations of the relevant IEC standards were elaborated ...
Rudolf N. KARYAKIN, Viktor G. LOSEV
openaire   +2 more sources

Overhead Line Electric Field on the Impact of Grounding Device Corrosion and Corrosion Prevention Strategies

2023 6th Asia Conference on Energy and Electrical Engineering (ACEEE), 2023
Overhead line grounding device conductivity for lightning strikes and other faults occurs when the energy drainage through is critical. The long-term operation of the grounding pole is affected by different degrees of corrosion, and the influence of line
Zhang Jun   +7 more
semanticscholar   +1 more source

Remote monitoring of the condition of the grounding device

Digital Technology Security, 2023
In connection with the rapid development of technologies, increasing the volume of data exchange and increasing requirements for information security, there is a need to pay special attention to the causes of possible data loss.
V. E. Mitrokhin, A. Naumov
semanticscholar   +1 more source

Application of ground penetrating radar to fault analysis in construction of grounding device

Other Conferences, 2021
Substation grounding device is a hidden project, there is no effective detection means for fault analysis. In this paper, the detection technology of ground penetrating radar is applied to the analysis of abnormal current when the grounding device of EHV
Wentao Chen, Tianbo Wu, Dilyar Dolkun
semanticscholar   +1 more source

Modelling of transmission tower considering the surge response of tower grounding device

Workshop on Automated Control for Datacenters and Clouds, 2020
Surge propagation on transmission tower is a concerning issue in lightning protection, particularly in predicting overvoltage on electrical power system as well as providing reference information for surge protection design. Transmission towers have been
W. Zaimuran   +5 more
semanticscholar   +1 more source

Grounding for surge-protective devices ground resistance versus ground impedance

2006 IEEE Power Engineering Society General Meeting, 2006
The aim of this paper is to address the often loosely used terms of impedance and resistance as related to grounding, and to educate the reader as to the significant difference between these two terms when contemplating the behavior of grounding systems impressed with transient impulse currents.
A.J. Surtees   +2 more
openaire   +1 more source

Method for Reducing Impulse Grounding Impedance of Grounding Device by Using Grounding Electrode with Non-uniform Radius

IEEE International Conference on High Voltage Engineering and Application, 2020
Reducing the transient grounding impedance of the grounding device is an important measure for lightning protection. However, due to the inductive reactance of the grounding electrode, the transient grounding impedance is usually very high.
Zhuoran Liu   +5 more
semanticscholar   +1 more source

Study on corrosion fracture diagnosis method of grounding wire of tower grounding device

, 2020
Tower grounding device provides the discharging channel for currents under lightning and fault. However, the grounding wire is prone to corrosion. Existing detection methods through measuring the grounding resistance to detect fracture, but it suffers ...
Zhanlong Zhang   +6 more
semanticscholar   +1 more source

Testing device for surgical grounding plates

Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society, 1992
This paper reports about a new device for safety test of disposable grounding plates for electrosurgery. Neutral electrodes (grounding plates, dispersive electrodes) must fulfill the requirements of the american AAMI HF-18 standard. Instead of measurements on human volunteers an electronic devive was built to simulate human skin. Its conductive surface
null Nessler, null Huter, null Wang
openaire   +1 more source

Home - About - Disclaimer - Privacy