Results 1 to 10 of about 4,455 (159)

Research on Discharging Current Distribution of Grounding Electrodes [PDF]

open access: yesIEEE Access, 2019
Grounding electrodes with good current discharging performance can ensure the reliability of power system security. Discharging current is not only the reason for accelerating the corrosion, but also the key indicator of the grounding electrodes ...
Zhanlong Zhang   +5 more
doaj   +4 more sources

Analysis the influence of corrosion layer on the grounding performance of grounding electrodes [PDF]

open access: yesIET Generation, Transmission & Distribution, 2020
The grounding electrode buried in soil is prone to corrosion affected by soil and leakage current. The surface of corroded grounding electrodes is wrapped with corrosion product, which affects the normal current dissipation process and weakens the ...
Zhanlong Zhang   +5 more
doaj   +3 more sources

Comprehensive evaluation of corroded grounding electrodes considering the impulse characteristics

open access: yesFrontiers in Materials, 2023
The grounding electrodes are buried in a harsh soil environment, which will cause corrosion. Corroded grounding electrodes directly affect the safe and stable operation of the power system.
Xuemeng Wang   +4 more
doaj   +3 more sources

Analysis of the effect of explosion grounding electrode on grounding resistance reduction

open access: yesThe Journal of Engineering, 2019
Developing cracks in the soil by means of explosions in the holes, as is called the explosion grounding electrode in this study, is a very effective way to reduce the grounding resistance in the area with high resistivity soil.
Yongli Wang   +4 more
doaj   +2 more sources

Performance of Grounding Electrodes Under Lightning Strokes in Uniform and Two-Layer Soils Considering Soil Ionization

open access: yesIEEE Access, 2022
This article presented the characteristics of the grounding electrodes in uniform and two layer soils when subjected to lightning including the impacts of soil ionization with frequency, soil resistivity, and permittivity variations.
Osama E. Gouda   +4 more
doaj   +3 more sources

Optimizing Microfluidic Impedance Cytometry by Bypass Electrode Layout Design [PDF]

open access: yesBiosensors
Microfluidic impedance cytometry (MIC) has emerged as a popular technique for single-cell analysis. Traditional MIC electrode designs consist of a pair of (or three) working electrodes, and their detection performance needs further improvements for ...
Guangzu Wu   +6 more
doaj   +2 more sources

Influence of lightning current surge shape and peak value on grounding parameters [PDF]

open access: yesBulletin of the Polish Academy of Sciences: Technical Sciences, 2021
Groundings are necessary parts included in lightning and shock protection. In the case of a surge current, high current phenomena are observed inside the grounding. They are result of the electrical discharges around the electrode when the critical field
Artur Łukaszewski, Łukasz Nogal
doaj   +1 more source

Research on Connection Scheme of HVDC WAN Grounding Electrode In Guangdong Based on Wide-Area Connection

open access: yes南方能源建设, 2021
[Introduction] To solve the problem of difficult site selection for grounding electrodes in HVDC transmission projects in Guangdong, this paper analyzes the connection of existing grounding electrodes to form a WAN grounding electrode for future DC ...
GAO Jia   +4 more
doaj   +1 more source

Research on the Interaction Between Multi-Circuit Shared HVDC Grounding Electrodes

open access: yes南方能源建设, 2023
[Introduction] Unlike the independent grounding electrode, shared earth electrode is connected to multiple DC (Direct Current) systems, and its parameters and operation mode need to be determined by each system connected to it.
Yu LIU, Wen WANG
doaj   +1 more source

Interference monitoring and influence rule of HVDC grounding electrode to buried pipelines

open access: yesYou-qi chuyun, 2021
In order to understand the influence rule of the grounding electrode of HVDC transmission engineering on the stray current of buried pipeline, the remote potential monitoring system was equipped for 12 pipelines near the 17 grounding electrodes of HVDC ...
Qinglin GU   +7 more
doaj   +1 more source