Results 111 to 120 of about 18,806 (286)

Analytical determination of participation in superconducting coplanar architectures

open access: yes, 2018
Superconducting qubits are sensitive to a variety of loss mechanisms which include dielectric loss from interfaces. The calculation of participation near the key interfaces of planar designs can be accomplished through an analytical description of the ...
Gambetta, Jay M.   +3 more
core   +1 more source

Cryo‐EM of Rationally Designed Photosystem I Nanoassembly on Graphene Validates Orientation‐Driven Enhancement of Photocatalytic Performance

open access: yesAdvanced Functional Materials, EarlyView.
The first cryo‐EM visualization and quantification of oriented Photosystem I (PSI) on single‐layer graphene is reported. Domain‐specific covalent anchoring of PSI, with the reducing side of the biophotocatalyst toward graphene, promotes three‐fold higher anodic photocurrent generation compared to a randomly physisorbed counterpart. This approach allows
Miriam Izzo   +6 more
wiley   +1 more source

Optical gyroscope system [PDF]

open access: yes, 1981
Light beams pass in opposite directions through a single mode fiber optic wave guide that extends in a circle or coil in an optical gyroscope system which measures the rotation rate of the coil by measuring the relative phase shifts of the beams by ...
Goldstein, R., Goss, W. C.
core   +1 more source

CRISPR/Cas9‐Assisted Microrobots for Fast and Ultrasensitive “On‐The‐Fly” Next‐Generation DNA Detection

open access: yesAdvanced Functional Materials, EarlyView.
This work presents self‐propelled CRISPR/Cas9‐functionalized Au–MRs for rapid, amplification‐free, “on‐the‐fly” DNA detection. By harnessing motion‐assisted signal recovery, the platform achieved the limit of detection in low fM DNA concentrations, enabling detection across a wide dynamic range within only 5 min, which is significantly faster than any ...
Jyoti   +3 more
wiley   +1 more source

Design of Grounding Grid for Main Substations in High Soil Resistivity Areas Based on CDEGS Software

open access: yesChengshi guidao jiaotong yanjiu
Objective To address the difficulty of reducing the grounding resistance of main substations in high soil resistivity areas, it is necessary to study the design of grounding grids for main substations in such regions.
CAO Jianshe
doaj   +1 more source

Performance criteria guideline for three explosion protection methods of electrical equipment rated up to 15,000 volts AC [PDF]

open access: yes
The Bureau of Mines, U.S. Department of the Interior, is reviewing explosion protection methods for use in gassy coal mines. This performance criteria guideline is an evaluation of three explosion protection methods of machines electrically powered with ...
Dunn, J. H., Linley, L. J., Luper, A. B.
core   +1 more source

Fast‐Responding O2 Gas Sensor Based on Luminescent Europium Metal‐Organic Frameworks (MOF‐76)

open access: yesAdvanced Functional Materials, EarlyView.
Luminescent MOF‐76 materials based on Eu(III) and mixed Eu(III)/Y(III) show rapid and reversible changes in emission intensity in response to O2 with very short response times. The effect is based on triplet quenching of the linker ligands that act as photosensitizers. Average emission lifetimes of a few milliseconds turn out to be mostly unaffected by
Zhenyu Zhao   +5 more
wiley   +1 more source

BEHAVIOUR OF BACKFILL MATERIALS FOR ELECTRICAL GROUNDING SYSTEMS UNDER HIGH VOLTAGE CONDITIONS [PDF]

open access: yesJournal of Engineering Science and Technology, 2015
Backfill materials like Bentonite and cement are effective in lowering grounding resistance of electrodes for a considerable period. During lightning, switching impulses and earth fault occurrences in medium and high voltage networks, the grounding ...
S. C. LIM   +4 more
doaj  

HV discharge acceleration by sequences of UV laser filaments with visible and near-infrared pulses

open access: yes, 2017
We investigate the triggering and guiding of DC high-voltage discharges over a distance of 37 cm by filaments produced by ultraviolet (266 nm) laser pulses of 200 ps duration.
Arissian, Ladan   +8 more
core   +2 more sources

Transparent Inorganic–Organic Bilayer Neural Electrode Array and Integration to Miniscope System for In Vivo Calcium Imaging and Electrophysiology

open access: yesAdvanced Functional Materials, EarlyView.
This study presents the BioCLEAR system, a highly transparent and conductive neural electrode array composed of silver nanowires (AgNWs) and doped PEDOT:PSS, enabling neural recordings with minimal optical artifacts. When integrated with a GRIN lens, this cost‐effective neural implant allows simultaneous electrophysiological recording and GCaMP6‐based ...
Dongjun Han   +17 more
wiley   +1 more source