Results 241 to 250 of about 931,771 (301)
Some of the next articles are maybe not open access.
IEEE Transactions on Instrumentation and Measurement
Different dc interference sources cause variations in ground potential distribution and have an effect on the choices of corrosion inhibition strategies. Therefore, accurate identification of the sources is of great significance.
Yidi Ma +4 more
semanticscholar +1 more source
Different dc interference sources cause variations in ground potential distribution and have an effect on the choices of corrosion inhibition strategies. Therefore, accurate identification of the sources is of great significance.
Yidi Ma +4 more
semanticscholar +1 more source
Grounding Grids Transient Simulation
IEEE Transactions on Power Delivery, 2005A transient grounding grid numerical model is developed. The results are compared with measurements done by other authors. The agreement between the simulations and measured data are completed with the comparison with theoretical results and concepts. Several cases with different soil parameters and grid geometry are presented.
openaire +1 more source
Resistance to ground and mesh voltages of ground grids
Proceedings of the Institution of Electrical Engineers, 1979The paper presents the results of a digital analysis of a wide set of square and rectangular grounding grids. The diagrams for grid resistances and mesh voltage factors are displayed appropriate for practical design purposes. Simple approximate formulas for both grid parameters considered are also proposed, providing a fair estimation of the parameters.
J. Nahman, S. Skuletich
openaire +1 more source
2018 International Conference On Advances in Communication and Computing Technology (ICACCT), 2018
In unequally spaced grounding grid the buried horizontal interconnected conductors are placed at unequal space in such a manner that denser and closely spaced grid conductors placed near periphery of the grid than center of the earth grid. So grounding grid design in unequally spaced manner may be more safe than equally spaced in which there are ...
Anup Kumar +2 more
openaire +1 more source
In unequally spaced grounding grid the buried horizontal interconnected conductors are placed at unequal space in such a manner that denser and closely spaced grid conductors placed near periphery of the grid than center of the earth grid. So grounding grid design in unequally spaced manner may be more safe than equally spaced in which there are ...
Anup Kumar +2 more
openaire +1 more source
Grid Enabled Ground Segment Systems
2005 IEEE Aerospace Conference, 2005Distributed architectures, commonly adopted by ground segment systems in order to cope with the large amounts of data and intensive computing associated with space missions, are now facing new scenarios with increasing data rates, larger archives and added-value services that call for the investigation of technologies capable of supporting these ...
openaire +1 more source
Interconnections criteria of grounding grids in global grounding systems
2018 IEEE/IAS 54th Industrial and Commercial Power Systems Technical Conference (I&CPS), 2018A Global Grounding System is defined as the combination of local grounding systems, obtained by their interconnection, which ensures, thanks to their proximity, that no dangerous touch voltages can arise. The interconnection of grounding systems via the armors of the MV cables, between secondary substations and HV/MV stations is herein analyzed to ...
M. L. DI Silvestre +7 more
openaire +1 more source
Improved Design of Square Grounding Grids
2006 International Conference on Power System Technology, 2006Vertical ground rods are the simplest and commonly used means for earth termination of electrical and lightning protection systems. It plays an important role when adding to the grounding grid to improve the performance of it by reducing not only the grid resistance but also the step and touch voltages to values that safe for human.
Sherif Ghoneim +3 more
openaire +1 more source
Relaxed hierarchical power/ground grid analysis
Proceedings of the ASP-DAC 2005. Asia and South Pacific Design Automation Conference, 2005., 2005This paper proposes a novel hierarchical approach to the efficient analysis of large VLSI power/ground grids. Different from the existing hierarchical approach where sub-circuit equivalent models are sparsified with computation-intensive integer programming and the resulting modeling may lead to larger errors if the top circuit matrix has large ...
Yici Cai +5 more
openaire +1 more source
Efficient Design On The Substation Grounding Grid: A Case Study at 2x500MVA Galang
2020 4rd International Conference on Electrical, Telecommunication and Computer Engineering (ELTICOM), 2020The design of the substation grounding system is very important to provide safety and protection for both the equipment and operators around it. To achieve this condition, the design must meet predetermined standards.
S. Hardi +3 more
semanticscholar +1 more source
Surface Potential Calculation for Grounding Grids
2006 IEEE International Power and Energy Conference, 2006One of tasks of the grounding systems is to maintain the voltage rise due to discharging fault current into grounding grids at the minimum value to insure the safety of public and personnel. The objective of the paper is to make a comparison between the addition of horizontal rods and vertical rods to the grounding grids to improve the performance of ...
Sherif Ghoneim +3 more
openaire +1 more source

