Results 241 to 250 of about 61,237 (302)

Half a century of dynamic instability following the ocean-driven break-up of Wordie Ice Shelf. [PDF]

open access: yesNat Commun
Dømgaard M   +7 more
europepmc   +1 more source
Some of the next articles are maybe not open access.

Related searches:

Optimization of SPIDER Grounded Grid Segment Design

IEEE Transactions on Plasma Science, 2022
The ITER Neutral Beam Test Facility (NBTF), built at Consorzio RFX in Padova, Italy, hosts two experimental devices aiming to test and optimize the ITER Heating Neutral Beam Injectors (HNBs) before construction and installation at ITER site. A full size ion source called SPIDER, producing a 5 MW D- or H- ion beam with 100 kV acceleration voltage, is ...
Pavel Tomsic   +5 more
openaire   +4 more sources

Transient performance of grounding grids

IEEE Transactions on Power Delivery, 1989
Understanding the behaviour of grounding systems to transient currents is important to establish the efficacy of protection offered by these systems to personnel and to the electrical installations against lightning. In this paper, an analytical method to determine the transient performance of grounding grids is presented.
M. Ramamoorty   +3 more
openaire   +3 more sources

Influence of Ground Rods on Grounding Grids

IEEE Transactions on Power Apparatus and Systems, 1979
Detailed analysis of ground rods and their influence on horizontal ground conductors, such as those forming grounding grids, is performed assuming a two layer soil stratification. The study starts with a discussion about the adequacy of uniform and two-layer soils as equivalent models for actual soil structures.
F. Dawalibi, D. Mukhedkar
openaire   +1 more source

Parametric Analysis of Grounding Grids

IEEE Transactions on Power Apparatus and Systems, 1979
The results of an extensive study conducted using a computer program designed to determine grounding performance in two-layer soils [1,2,3,5] are described and discussed. A variety of grounding grid configurations and two-layer soil conditions are analysed in detail.
F. Dawalibi, D. Mukhedkar
openaire   +1 more source

Impulse Impedance of Grounding Grids

IEEE Transactions on Power Apparatus and Systems, 1980
A method and an empirical formula to calculate the inductance of square grounding grids fed at either centre or one of the corners is presented. Empirical formulae for the effective area and impulse coefficient for centre fed and corner fel square grids are determinel.
B.R. Gupta, B. Thapar
openaire   +1 more source

Nonuniform Semi-Infinite Grounded Grids

SIAM Journal on Mathematical Analysis, 1982
Semi-infinite resistive grounded grids are countably infinite electrical networks that arise from the discretization of the partial differential equation governing the minority-carrier density in a doped semiconductor. If the doping varies with depth from the surface of the semiconductor, the grid’s resistances also vary with distance from the inputs ...
openaire   +2 more sources

Resonant grounded grids - quo vadis!?

IET Conference Publications, 2009
In earth fault compensated networks the basically capacitive earth fault current is counterbalanced by the injection of an inductive current through the arc suppression coils in such a way, that for most overhead line faults these arcs extinguish without the necessity of disconnecting the faulty grid section.
L. Fickert   +4 more
openaire   +1 more source