Results 161 to 170 of about 8,476 (216)
Conversational Multi-Agentic Network-Driven Disease Module Identification and Drug Repurposing Prediction With ChatDRex: Platform Development Study. [PDF]
Süwer S +7 more
europepmc +1 more source
Enhancing the Predictive Value of Formative Evaluation in Extended Reality Adoption: Addressing the Experience Gap. [PDF]
Ferrer Costa J, Armayones Ruiz M.
europepmc +1 more source
The PERI Model of Radical Healing as a Framework for Advancing Perinatal Mental Health. [PDF]
Mujica CA, Lee BA, Jarnecke AM.
europepmc +1 more source
Fault Location of Generator Stator with Single-Phase High-Resistance Grounding Fault Based on Signal Injection. [PDF]
Lei B +7 more
europepmc +1 more source
Electrostatic Discharge During Helicopter Hoist Operations: A Nationwide Prospective Study of the Norwegian Search and Rescue Service. [PDF]
Brede JR +3 more
europepmc +1 more source
Some of the next articles are maybe not open access.
Related searches:
Related searches:
IEEE Transactions on Industry Applications, 2015
In cases where the grounding system is buried in soils characterized by poor contact with the electrodes (e.g., karst and sandy terrains), the contact resistance frequently represents a dominant component of the total grounding resistance. In such cases, estimation of the grounding resistance by conventional formulas given in the literature is useless,
Jovan Trifunovic, Miomir Kostic
exaly +2 more sources
In cases where the grounding system is buried in soils characterized by poor contact with the electrodes (e.g., karst and sandy terrains), the contact resistance frequently represents a dominant component of the total grounding resistance. In such cases, estimation of the grounding resistance by conventional formulas given in the literature is useless,
Jovan Trifunovic, Miomir Kostic
exaly +2 more sources
IEEE Power Engineering Review, 1989
The nature of ground resistance is examined to explain the high impedance of faults directly to ground as contrasted to conventionally assumed low-impedance ground faults to neutral conductors or to towers with low footing resistance. High-impedance faults are shown to be inherently nonlinear due to the characteristics of soil.
Donald I. Jerrings, John R. Linders
openaire +2 more sources
The nature of ground resistance is examined to explain the high impedance of faults directly to ground as contrasted to conventionally assumed low-impedance ground faults to neutral conductors or to towers with low footing resistance. High-impedance faults are shown to be inherently nonlinear due to the characteristics of soil.
Donald I. Jerrings, John R. Linders
openaire +2 more sources
Evaluation of ground resistance of a grounding grid of any
IEEE Power Engineering Review, 1991A large number of grounding grids in substations have shapes other than a square or a rectangle, whereas the formulas and graphs for the ground resistance of a grounding grid available in the literature are applicable only to nearly square or rectangular grids.
B. Thapar +3 more
openaire +1 more source

