Results 11 to 20 of about 23,164 (247)
Energized Diagnostic Technology of Cable Cross-Bonded Defects
A new type of energized diagnostic technique aimed at defects in the cross-bonded grounding system of power cables is proposed. Based on the equivalent model of a normal cross-bonded grounding unit, the equivalent models of 23 common cross-bonded defects
Shunyu Yao, Zhen Liu
doaj +1 more source
Effect of Non-Homogeneous Soil Characteristics on Substation Grounding-Grid Performances: A Review
Designing an effective grounding system for AC substations needs predetermination of ground resistance and ground potential distribution caused by fault current’s presence in the ground.
Navinesshani Permal +3 more
doaj +1 more source
Reduction of the step voltages of MV/LV substation grounding system based on shaping electric field [PDF]
The article presents the analysis results of the effectiveness limitation of the step voltage by forming an electric field on the ground surface. For shaping the electric field, a method consisting of screens placed around the point of the earth current ...
Roman Sikora, Przemysław Markiewicz
doaj +1 more source
It is important to ensure that a grounding system is designed with a low magnitude of earth resistance, so the protection system can divert the large fault current to earth effectively.
Navinesshani Permal +3 more
doaj +1 more source
Gas insulated transmission line (GIL) is an advanced power transmission mode. Since the extension of this kind of equipment is relatively long, the grounding design and layout of the GIL will have a direct impact on personal safety and the stability ...
Chun Zhao +5 more
doaj +1 more source
In order to enhance the security of ±800 kV High-Voltage DC (HVDC) system, it is needed to consider and analyze the grounding mode of the neutral point of converter transformer.
Jiaqing Fu +4 more
doaj +1 more source
Grounding System Cost Analysis Using Optimization Algorithms
In this study, the concept of grounding systems is related to the voltage tolerance of the human body (human body voltage tolerance safety value). The maximum touch voltage target and grounding resistance values are calculated in order to compute the ...
Jau-Woei Perng +2 more
doaj +1 more source
Lightning Performance Evaluation of Italian 150 kV Sub-Transmission Lines
A significant majority of overhead transmission lines’ (OHLs) outages is due to backflashovers caused by direct lightning strikes: the realistic assessment of the lightning performance is thus an important task.
Fabio Massimo Gatta +4 more
doaj +1 more source
Simulation and Experiment Analysis of 10 kV Flexible Grounding Device
The traditional 10 kV distribution network grounding system has some disadvantages, such as small grounding current and poor arc extinguishing effect, thus, hindering the detection of high-resistance grounding fault.
Mengxuan Liu, Chi Zhang, Kangli Liu
doaj +1 more source
Purpose. The purpose of the work is to develop the fundamentals of the design methodology of grounding system design of substations with open switchgears 330 (220) kV, which is aimed at ensuring electromagnetic compatibility of secondary circuits of ...
O. Yu. Glebov +3 more
doaj +1 more source

