Results 1 to 10 of about 278,093 (202)
For high-voltage (HV) AC cable transmission systems, the metal sheaths of three separate single-core cables are cross-bonded at each end of the cable section, to suppress the induced voltages in sheaths.
Zhonglei Li, Boxue Du, Boxue Du, Wang Li
doaj +3 more sources
In the present study, field tests were performed using low-resistivity materials (LRMs) in different grounding system (GS) configurations to reduce the grounding resistance (GR) and assess the variation in the effectiveness of the LRMs with increases in ...
Freddy Sinchi-Sinchi +3 more
doaj +3 more sources
Overview of Transient Simulations of Grounding Systems under Surge Conditions
The present paper gives an overview of modelling methods of standard grounding systems under surge conditions, using the non-uniform transmission line approach.
Tomasz Kisielewicz, Milton Cuenca
doaj +3 more sources
Seasonal Influences on the Impulse Characteristics of Grounding Systems for Tropical Countries
One of the most important parameters of the performance of grounding systems is the soil resistivity. As generally known, the soil resistivity changes seasonally, hence the performance of grounding systems, at DC and under high impulse conditions.
Muhd Shahirad Reffin +6 more
doaj +3 more sources
Performance of Practical Grounding Systems under High Impulse Conditions
This paper investigates the factors affecting the impulse characteristics of purposely built grounding systems. We installed 2 m × 2 m grounding systems in four different sites with different soil resistivity values.
Muhd Shahirad Reffin +3 more
doaj +3 more sources
Time domain solution of electromagnetic radiation model of the grounding system excited by pulse current [PDF]
This paper deals with an advanced electromagnetic radiation approach for analyzing the time-domain performance of grounding systems under pulse excitation currents.
Dautbašić Nedis J. +1 more
doaj +1 more source
Research on the Interaction Between Multi-Circuit Shared HVDC Grounding Electrodes
[Introduction] Unlike the independent grounding electrode, shared earth electrode is connected to multiple DC (Direct Current) systems, and its parameters and operation mode need to be determined by each system connected to it.
Yu LIU, Wen WANG
doaj +1 more source
Effect of Impulse Polarity on a New Grounding Device with Spike Rods (GDSR)
The characterizations of grounding systems subjected to high impulse conditions are known to be dependent on the polarity, current to peak time and discharge time, as well as the electrical properties of the soil, and the grounding electrodes themselves.
Abdul Wali Abdul Ali +2 more
doaj +1 more source
Substations are important parts of electric power systems, and they require well-designed grounding systems. A proper grounding system guarantees the safety of the personnel working in an environment surrounded by grounded equipment from possible ...
Navinesshani Permal +3 more
doaj +1 more source
Ionisation can occur in the soil when high impulse currents are subjected to grounding systems. This occurrence is generated by a difference in the dielectric strength value between the soil and air voids.
Hanis Hamizah Hizamul-Din +3 more
doaj +1 more source