Results 91 to 100 of about 382,087 (139)

Workflow to facilitate complete denture scanning with an intraoral scanner: A technique report

open access: yesJournal of Prosthodontics, EarlyView.
Abstract Scanning a denture with an intraoral scanner is typically more challenging than scanning a dentate arch. This article describes a novel technique for digitally duplicating a complete denture. The workflow involves scanning an existing denture using an intraoral scanner with the addition of specific markers and subsequently constructing a ...
Jiayi Yu   +3 more
wiley   +1 more source

Visitors Guiding Principles

open access: yes, 2020
These Guiding Principles are intended to support services when revising their local policies and procedures developed to meet the Schedule V requirements of the Health Act 2007 (Care and Support of Residents in Designated Centres for persons with ...
National Disability Services Quality Improvement Office, Guiding Principles Subgroup
core  

A digital workflow for full‐arch implant fixed prosthesis: Clinical application of a 3D‐printed polychromatic flangeless trial denture, anatomic bone reduction guide, and intraoral scanning for definitive prosthesis fabrication

open access: yesJournal of Prosthodontics, EarlyView.
Abstract This clinical report presents a comprehensive digital workflow for rehabilitating a patient with maxillary terminal dentition using a full‐arch, implant‐supported fixed dental prosthesis (FP‐1). It highlights the integration of a 3D‐printed polychromatic flangeless trial denture and a customized anatomic bone reduction template, enabling ...
Weiqing Liu   +2 more
wiley   +1 more source

Prosthetic designs for complete dentures manufactured using contemporary 3D printing techniques: A case series with clinical, design, and laboratory considerations

open access: yesJournal of Prosthodontics, EarlyView.
Abstract Advancements in additive manufacturing have enabled the precise fabrication of complete dentures using modern photopolymers and diverse 3D printing techniques. These innovations have transformed removable prosthodontics by allowing clinicians to design and manufacture highly customized prostheses to manage difficult anatomical and esthetic ...
Francisco X. Azpiazu‐Flores   +4 more
wiley   +1 more source

Peri‐implantitis—Is it mainly a clinician‐initiated complication of implant therapy?

open access: yesPeriodontology 2000, EarlyView.
Abstract Aim The high prevalence of peri‐implantitis is concerning, with a growing consensus that the majority of cases are complications initiated by clinician‐related errors rather than classic pathology. A primary predisposing factor for peri‐implantitis is exposure of the micro‐rough implant surfaces to the peri‐implant sulcus after treatment ...
Stephen T. Chen   +9 more
wiley   +1 more source

Initial Experience With Endoscopic Ultrasound‐Guided Gallbladder Drainage Using Lumen‐apposing Metal Stents in Extremely Elderly and Frail Patients

open access: yesDEN Open, Volume 7, Issue 1, April 2027.
ABSTRACT Objectives Endoscopic ultrasound‐guided gallbladder drainage (EUS‐GBD) using lumen‐apposing metal stents (LAMS) is a treatment option for acute cholecystitis in high‐risk surgical patients. However, data on extremely elderly and frail patients are limited. We report our initial experience with EUS‐GBD using electrocautery‐enhanced LAMS in this
Kiyoyuki Kobayashi   +16 more
wiley   +1 more source

Comparison of Two Partially Covered Metal Stents for Endoscopic Ultrasound‐guided Hepaticogastrostomy: A Multi‐Center Retrospective Study

open access: yesDEN Open, Volume 7, Issue 1, April 2027.
ABSTRACT Objectives Endoscopic ultrasound‐guided hepaticogastrostomy (EUS‐HGS) is an alternative biliary drainage method after failed endoscopic retrograde cholangiopancreatography. Nevertheless, it is associated with adverse events (AEs), including peritonitis and stent migration.
Masahiro Yamamura   +17 more
wiley   +1 more source

Nonlinear Flange Curling of Wide-flange Sections (No. R850)

open access: yes, 2005
This report describes the experimental and theoretical analysis of flange curling deformations. Flange curling of two commercially available roof sheeting profiles named Monoclad and Megaclad provided by Stramit Building Industries have been examined ...
Lecce, Maura, Rasmussen, Kim J.R.
core  

Enhancing the Seismic Resilience of Masonry‐Infilled RC Structures Using Rubber Joints: Full‐Scale 3D Shaking Table Tests

open access: yesEarthquake Engineering &Structural Dynamics, Volume 55, Issue 15, Page 4088-4112, December 2026.
ABSTRACT Masonry infills in reinforced concrete (RC) frames are highly vulnerable to seismic damage, often sustaining severe cracking even under moderate ground motion, which in turn leads to considerable economic losses and safety risks. To address this issue, this study experimentally evaluates the effectiveness of two innovative rubber‐based joints ...
Enrico Tubaldi   +16 more
wiley   +1 more source

Multiscale Modelling of Frame Structures With Lattice‐Like Mesostructures Using Finite Beam Elements at the Macro and Meso Level

open access: yesProceedings in Applied Mathematics and Mechanics, Volume 26, Issue 4, December 2026.
ABSTRACT In this contribution, we present a FE2${\rm FE}^2$ model for shear‐flexible beams with a lattice‐like meso structure. The meso structure consists of a network of beams. The meso ‐ and macroscale are coupled by means of the Hill–Mandel condition.
Julian Ochs, Jens Wackerfuß
wiley   +1 more source

Home - About - Disclaimer - Privacy