Results 211 to 220 of about 329,894 (240)
Some of the next articles are maybe not open access.
Guided acoustic wave interaction with flanged junctions in water-filled steel pipelines
The Journal of the Acoustical Society of America, 2018The interactions of guided acoustic waves with pipelines and associated components has become a topic of interest due to their application in water pipeline condition assessment. In this paper, guided acoustic wave interactions with flanged junctions in a water-filled pipeline are investigated by an analytical model and experimental measurements.
Li, Zhao ECE +4 more
openaire +3 more sources
Tape edge study in a linear tape drive with single-flanged guides
Journal of Magnetism and Magnetic Materials, 2004Improved tape guiding and tape dimensional stability are essential for magnetic tape linear recoding formats to take advantage of vastly increased track density and thereby achieve higher storage capacities. Tape guiding is dependent on numerous parameters, such as type of the guides and tape path geometry, quality of virgin tape edge, drive operating ...
Anton V. Goldade, Bharat Bhushan
openaire +1 more source
Application of Nonlinear Guided Waves for Detecting Loose Flanged Bolted Joints in Pipelines
2021Guided waves are finding more applications for structural health monitoring of pipelines and other long, slender structures, particularly in the areas of corrosion and crack detection. Bolted joints are widely used in engineering structures in oil and gas, aerospace and civil structures.
Reza Soleimanpour +3 more
openaire +1 more source
Diffraction at the flanged open end of a planar irregular guide
Radiophysics and Quantum Electronics, 1990A new form of Galerkin's incomplete method is used with semireversal in the boundary conditions to obtain a rigorous solution for the diffraction of a H-polarized wave at the open end of a planar smoothly irregular guide fitted with an infinite flange.
openaire +1 more source
Journal of Prosthodontics, 2014
AbstractPurposeThis report describes the efficacy of a guiding flange appliance in correcting mandibular deviation in the hemi‐mandibulectomy patient and correlates the time elapsed between surgery and placement of the appliance and the extent of initial mandibular deviation to the success rate of a guiding flange appliance in correcting the deviation ...
Arvind, Tripathi +4 more
openaire +2 more sources
AbstractPurposeThis report describes the efficacy of a guiding flange appliance in correcting mandibular deviation in the hemi‐mandibulectomy patient and correlates the time elapsed between surgery and placement of the appliance and the extent of initial mandibular deviation to the success rate of a guiding flange appliance in correcting the deviation ...
Arvind, Tripathi +4 more
openaire +2 more sources
Indian Journal of Forensic Medicine & Toxicology, 2020
Defects with the discontinuity of the mandible following a segmental mandibulectomy present a majorchallenge for rehabilitation. These challenges include correction of deranged mandibular movements,disfigurement, and esthetics, correction of functional difficulty seen during swallowing,speech andarticulation, and also of surgical side deviation of the ...
openaire +1 more source
Defects with the discontinuity of the mandible following a segmental mandibulectomy present a majorchallenge for rehabilitation. These challenges include correction of deranged mandibular movements,disfigurement, and esthetics, correction of functional difficulty seen during swallowing,speech andarticulation, and also of surgical side deviation of the ...
openaire +1 more source
A piezoelectric guided wave sensor design method for crack monitoring of I-beam flanges
Measurement Science and TechnologyAbstract I-beams are widely used in industrial structural engineering, but their flanges are prone to localized damage during service. Ultrasonic guided waves have long-distance propagation capabilities in cross-section steel structures, making them suitable for damage monitoring of I-beams. However, existing test
Dengke Zhang +3 more
openaire +1 more source
Management of a Hemi-Mandibulectomy defect with a definitive Guiding Flange Prosthesis
Pushpagiri Medical Journal, 2012Aby Mathew, Sebastian Thomas
openaire +1 more source
Structural Behavior of L-Type Flange Joint with Various Flange Flatness Conditions
Energies, 2023Thanh-Tuan Tran +2 more
exaly

