Results 11 to 20 of about 471,488 (122)

No difference in patella mobility between conventional mechanically aligned and robotic‐assisted functionally aligned total knee arthroplasty [PDF]

open access: yesKnee Surgery, Sports Traumatology, Arthroscopy, Volume 34, Issue 11, Page 4076-4081, November 2026.
Abstract Purpose Robotic‐assisted (RA) surgery allows for higher accuracy in total knee arthroplasty (TKA) and for better standardization of alignment concepts. It was hypothesized that the more personalized component placement in functional robotic‐assisted total knee arthroplasty (RA‐TKA) would show an impact on patella mobility and clinical outcome.
Krzysztof Lachowski   +5 more
wiley   +2 more sources

Consensus Report of Group 4 of the 1st Global Consensus for Clinical Guidelines for the Rehabilitation of the Edentulous Maxilla: Conventional Dentures, Implant Overdentures and Implant‐Supported Fixed Dental Prostheses [PDF]

open access: yesClinical Oral Implants Research, Volume 37, Issue S30, Page S81-S107, February 2026.
ABSTRACT Objectives The 1st Global Consensus for Clinical Guidelines (GCCG) in Implant Dentistry introduced an innovative, evidence‐based, patient‐centred approach to developing practical recommendations for the rehabilitation of the edentulous maxilla.
Charlotte Stilwell   +23 more
wiley   +2 more sources

Effect of sagittal alignment on patient outcomes following total knee replacement: A systematic review and correlation analysis [PDF]

open access: yesJournal of Experimental Orthopaedics, Volume 13, Issue 2, April 2026.
Abstract Purpose With enhanced implant precision facilitated by robotic technologies, there is renewed attention on the contribution of total knee replacement (TKR) alignment to the 20% post‐operative dissatisfaction rate. Although coronal alignment has been extensively studied, the impact of post‐operative sagittal alignment on patient‐reported ...
Prakrit R. Kumar   +8 more
wiley   +2 more sources

Cold-formed steel sections with web openings subjected to web crippling under two-flange loading conditions — Part II : Parametric study and proposed design equations [PDF]

open access: yes, 2012
A parametric study of cold-formed steel sections with web openings subjected to web crippling was undertaken using finite element analysis, to investigate the effects of web holes and cross-section sizes on the web crippling strengths of channel sections
Uzzaman, Asraf   +11 more
core   +4 more sources

Stamina of a non-gasketed flange joint under combined internal pressure and axial loading [PDF]

open access: yes, 2008
The performance of a bolted flange joint is characterized mainly by its 'strength' and 'sealing capability'. A number of numerical and experimental studies have been conducted to study these characteristics under internal pressure loading conditions ...
Abid, M.   +5 more
core   +4 more sources

A parametric study of metal-to-metal contact flanges with optimised geometry for safe stress and no-leak conditions [PDF]

open access: yes, 2004
This paper presents the results of a parametric study of the behaviour of metal-to-metal contact flanges that have different surface profiles. Using a finite element analysis approach, the important stress values in the flange and bolts and flange ...
Abid, M., Nash, D.H.
core   +4 more sources

Definitive mandibular guide flange prosthesis pada pasien pasca hemimandibulektomi dekstra

open access: yes, 2023
Tindakan operasi pada daerah maksilofasial dapat mengakibatkan cacat wajah, gangguan fungsi bicara, penelanan, pengunyahan, estetik serta gangguan kejiwaan.
Saleh, Suparyono   +3 more
core   +3 more sources

Leakage analysis of gasketed flange joints under combined internap pressure and thermal loading [PDF]

open access: yes, 2011
Leakage in Gasketed Flanged Joints (GFJs) have always been a great problem for the process industry. The sealing performance of a GFJ depends on its installation and applied loading conditions.
Khan, Kamran Ahmed   +3 more
core   +3 more sources

Acknowledgment to Reviewers of Prosthesis in 2020

open access: yes, 2021
Peer review is the driving force of journal development, and reviewers are gatekeepers who ensure that Prosthesis maintains its standards for the high quality of its published papers [...
Prosthesis Editorial Office Prosthesis Editorial Office   +1 more
core   +1 more source

Prosthodontic Approaches in Compromised Hemimandibulectomy Rehabilitation: A Case Series and Treatment Algorithm

open access: yesIndian Journal of Dental Sciences
Hemimandibulectomy, a surgical intervention often necessitated by neoplastic conditions or trauma, poses substantial challenges to both form and function within the oral cavity.
M. Shalini, Satish Kumar Gupta
doaj   +1 more source

Home - About - Disclaimer - Privacy