Results 251 to 260 of about 46,834 (302)
Haemodialysis-Induced Hypoglycaemia and Glycaemic Disarrays [PDF]
In patients with diabetes receiving chronic haemodialysis, both very high and low glucose levels are associated with poor outcomes, including mortality.
Kamyar Kalantar-Zadeh, Masanori Abe
exaly +2 more sources
Some of the next articles are maybe not open access.
Related searches:
Related searches:
Medical Journal of Australia, 1979
Thirty of the 39 patients treated at the Blacktown Dialysis Centre, the first "satellite" dialysis centre in the greater metropolitan Sydney, had been referred from four Sydney renal units for long-term dialysis therapy. The move save approximately 150 kilometres in travelling and eight hours time each week for each of these patients.
R N, Corcoran, J, Stephenson
+7 more sources
Thirty of the 39 patients treated at the Blacktown Dialysis Centre, the first "satellite" dialysis centre in the greater metropolitan Sydney, had been referred from four Sydney renal units for long-term dialysis therapy. The move save approximately 150 kilometres in travelling and eight hours time each week for each of these patients.
R N, Corcoran, J, Stephenson
+7 more sources
The Lancet, 1999
This paper charts the development of haemodialysis, the cornerstone of renal replacement therapy (RRT). It has enabled patients with end-stage renal failure to survive for years, in many cases with a surprisingly good quality of life. Through technological advances, RRT can be offered to patients who are older and more frail.
N P, Mallick, R, Gokal
openaire +2 more sources
This paper charts the development of haemodialysis, the cornerstone of renal replacement therapy (RRT). It has enabled patients with end-stage renal failure to survive for years, in many cases with a surprisingly good quality of life. Through technological advances, RRT can be offered to patients who are older and more frail.
N P, Mallick, R, Gokal
openaire +2 more sources
Thrombosis Research, 1990
The usability of recombinant hirudin as anticoagulant agent in haemodialysis was studied in nephrectomized dogs. To this end, we examined the capability of recombinant hirudin to penetrate the membranes of different capillary dialyzers used. Furthermore we investigated the pharmacokinetic behaviour of recombinant hirudin in nephrectomized dogs as well ...
E, Bucha, F, Markwardt, G, Nowak
openaire +2 more sources
The usability of recombinant hirudin as anticoagulant agent in haemodialysis was studied in nephrectomized dogs. To this end, we examined the capability of recombinant hirudin to penetrate the membranes of different capillary dialyzers used. Furthermore we investigated the pharmacokinetic behaviour of recombinant hirudin in nephrectomized dogs as well ...
E, Bucha, F, Markwardt, G, Nowak
openaire +2 more sources
Nature Reviews Nephrology, 2018
Haemodialysis is an extracorporeal process in which the blood is cleansed via removal of uraemic retention products by a semipermeable membrane. Traditionally, dialysis membranes have been broadly classified on the basis of their composition (cellulosic or noncellulosic) and water permeability (low flux or high flux).
Claudio, Ronco, William R, Clark
openaire +2 more sources
Haemodialysis is an extracorporeal process in which the blood is cleansed via removal of uraemic retention products by a semipermeable membrane. Traditionally, dialysis membranes have been broadly classified on the basis of their composition (cellulosic or noncellulosic) and water permeability (low flux or high flux).
Claudio, Ronco, William R, Clark
openaire +2 more sources
Pediatric Nephrology, 2012
Haemodialysis (HD) began as an intensive care treatment offered to a very select number of patients in an attempt to keep them alive. Outcomes were extremely poor, and the procedure was cumbersome and labor intensive. With increasing expertise and advances in dialysis equipment, HD is now recognised as a life-sustaining treatment that is considered a ...
Daljit K, Hothi +2 more
openaire +2 more sources
Haemodialysis (HD) began as an intensive care treatment offered to a very select number of patients in an attempt to keep them alive. Outcomes were extremely poor, and the procedure was cumbersome and labor intensive. With increasing expertise and advances in dialysis equipment, HD is now recognised as a life-sustaining treatment that is considered a ...
Daljit K, Hothi +2 more
openaire +2 more sources
Research in Experimental Medicine, 1978
A plate dialyser requiring an extracorporeal blood volume of 1.5 ml was developed to dialyse conscious rats. In experiments in vitro and in vivo its function was tested. The in vitro clearances of urea, creatinine and potassium were 126+/-9 ml/min/m2, 70.5+/-9 ml/min/m2, and 132.5+/-13 ml/min/m2, respectively.
A, Röckel +6 more
openaire +2 more sources
A plate dialyser requiring an extracorporeal blood volume of 1.5 ml was developed to dialyse conscious rats. In experiments in vitro and in vivo its function was tested. The in vitro clearances of urea, creatinine and potassium were 126+/-9 ml/min/m2, 70.5+/-9 ml/min/m2, and 132.5+/-13 ml/min/m2, respectively.
A, Röckel +6 more
openaire +2 more sources
Haemodialysis and helplessness
Nursing Standard, 1991Patients receiving haemodialysis might experience more feelings of helplessness than their counterparts on continuous ambulatory peritoneal dialysis (CAPD).
openaire +2 more sources
Acta Paediatrica, 1966
SummaryThirty two haemodialyses were carried out in six infants and eight small children using one half of the Kolff twin‐coil artificial kidney. The patients' weights ranged from 3.4 kg (7+½ lbs) to 29.5 kg (65 lbs). The danger of producing a significant change in the patient's blood volume was avoided by continuous weight recording during dialysis ...
H A, Lee, P, Sharpstone
openaire +2 more sources
SummaryThirty two haemodialyses were carried out in six infants and eight small children using one half of the Kolff twin‐coil artificial kidney. The patients' weights ranged from 3.4 kg (7+½ lbs) to 29.5 kg (65 lbs). The danger of producing a significant change in the patient's blood volume was avoided by continuous weight recording during dialysis ...
H A, Lee, P, Sharpstone
openaire +2 more sources
2020
Abstract Maintenance haemodialysis (HD) is a highly successful treatment for patients with established renal failure and is the default therapy when other renal replacement therapy options are not available. HD uses the countercurrent flow of blood and dialysate through a hollow fibre dialyser to maximize the concentration gradient ...
Jack Fairweather +2 more
openaire +2 more sources
Abstract Maintenance haemodialysis (HD) is a highly successful treatment for patients with established renal failure and is the default therapy when other renal replacement therapy options are not available. HD uses the countercurrent flow of blood and dialysate through a hollow fibre dialyser to maximize the concentration gradient ...
Jack Fairweather +2 more
openaire +2 more sources

