Results 151 to 160 of about 10,643,801 (300)

Defect‐Engineered ZnO Nanowire Arrays for Flexible Room‐Temperature Hydrogen Sensors

open access: yesAdvanced Materials Technologies, EarlyView.
Fabrication process of patterned ZnO nucleation sites on a flexible polyimide (PI) substrate. Top/tilted‐view SEM images of ordered ZnO nanoflower arrays confined within patterned circular regions. AFM topography map with height data revealing a disk‐array structure, where the patterned regions (marked by a red dot circle) are elevated by ∼2 µm ...
Jun‐Ting Wang   +7 more
wiley   +1 more source

Gate-Tunable Remnant Anomalous Hall Effect in Dual-‍Proximity Graphene Heterostructures. [PDF]

open access: yesSmall Sci
Satheesh S   +9 more
europepmc   +1 more source

Toward Perception‐Native Electronic Skin: Bio‐Inspired In‐/Near‐Sensor and Neuromorphic Computing for Humanoid Robots

open access: yesAdvanced Materials Technologies, EarlyView.
Dense tactile streams from across the humanoid body converge on collide in a central wiring and data bottleneck. By relocating computation closer to and then into the skin itself, near‐ and in‐sensor architectures, together with neuromorphic computing, chart a path toward perception‐native electronic skin, in which the conversion of stimulus into ...
Mijin Kim   +6 more
wiley   +1 more source

George W. Hall letter

open access: yes
This collection contains a letter written at Van Buren, Ark., by George W.
Hall, George W., 1805-?
core   +1 more source

Conductive Tin Oxide Under the Thermal Budget of Perovskite/TOPCon Tandems: Toward Indium‐Free Contacts

open access: yesAdvanced Materials Technologies, EarlyView.
This work demonstrates that achieving conductive undoped SnOx contacts required careful tailoring of oxygen vacancy (VO) tuning and defect engineering. Controlling oxygen deposition pressure and low‐temperature annealing (300°C) optimizes defect stoichiometry and mitigates carrier scattering. This low thermal budget approach significantly enhances Hall
Paul Llontop   +13 more
wiley   +1 more source

A Proof‐of‐Concept Assessment of a Novel Wearable Eyelid Muscle Device: A Pre‐Clinical Animal Cadaver Study for Eyelid Closure Restoration

open access: yesAdvanced Robotics Research, EarlyView.
This article introduces a soft wearable eyelid sling device incorporating a hydraulic soft artificial muscle (SAM) for achieving complete closure of an eyelid. The SAM is driven by a cam mechanism that provides a displacement profile closely matched with those of a healthy eyelid.
Patrick Pruscino   +7 more
wiley   +1 more source

Home - About - Disclaimer - Privacy