A NEW STRUCTURE OF FIVE-LEVEL DIODE CLAMPED INVERTER WITH REDUCING ITS ELEMENTS
At the high power switching circuit's applications, when the harmonic distortion is harmful, a multi-level diode clamped inverter is useful, especially when reduced total harmonic distortion and high power are desired.
Othman M. Anssari
doaj +1 more source
Comparison of different optimization criteria for optimal sizing of hybrid active power filters parameters [PDF]
Praise Worthy Prize granted a permission for Brunel University London to archive this article in BURA.Harmonic distortion in power systems has increased considerably due to the increasing use of nonlinear loads in industrial firms and elsewhere.
Elmathana, KTM, Zobaa, AF
core +1 more source
Optimal Harmonic Mitigation in Distribution Systems with Inverter Based Distributed Generation
In recent years, with the widespread use of non-linear loads power electronic devices associated with the penetration of various renewable energy sources, the distribution system is highly affected by harmonic distortion caused by these sources. Moreover,
Ahmed S. Abbas +6 more
doaj +1 more source
MSSB to Prevent Cable Termination Faults for Long High Voltage Underground Cable Lines
Cable termination fault is one of the most important problems for high voltage underground cable lines (HVUCL). Harmonic current (HC) and the sheath current (SC) are causes of cable termination faults of HVUCL.
Bahadir Akbal
doaj +1 more source
The electrical energy demand is steadily growing, and hence, the integration of photovoltaic system to the distribution networks is also dramatically increasing though it has a significant effect on the network’s power quality.
Estifanos Abeje Sharew +2 more
doaj +1 more source
Circuit Structure and Control Method to Reduce Size and Harmonic Distortion of Interleaved Dual Buck Inverter [PDF]
A new circuit structure and control method for a high power interleaved dual-buck inverter are proposed. The proposed inverter consists of six switches, four diodes and two inductors, uses a dual-buck structure to eliminate zero-cross distortion, and ...
Cho, Min-Gi +4 more
core +1 more source
Behavior of single-point harmonic producer indicators in electrified AC railways [PDF]
Electrified railways are an example of AC single phase distribution networks. A non-negligible amount of active and nonactive power may be related to harmonics, especially for distorted highly-loaded systems.
Andrea Mariscotti
doaj +1 more source
Interpretation of partial discharge activity in the presence of harmonics [PDF]
Recent work has identified that circumstances of equipment operation can radically change condition monitoring data. This contribution investigates the significance of considering circumstance monitoring on the diagnostic interpretation of such condition
Bahadoorsingh, S. +4 more
core +1 more source
Geomagnetically Induced Currents and Harmonic Distortion: High Time Resolution Case Studies
High time resolution (1–5 s) magnetometer, geomagnetically induced current (GIC), and mains harmonic distortion data from the Halfway Bush substation in Dunedin, New Zealand, are analyzed.
Mark A. Clilverd +6 more
doaj +1 more source
Grid background and dead‐time harmonic perturbations pose challenges in maintaining power quality and stability in the grid integration of renewable energy conversion systems.
Daniel Memije +4 more
doaj +1 more source

