Results 41 to 50 of about 81,530 (345)
Design and Development of a Class EF2 Inverter and Rectifier for Multi-megahertz Wireless Power Transfer Systems [PDF]
This paper presents the design and implementation of a Class EF2 inverter and Class EF2 rectifier for two -W wireless power transfer (WPT) systems, one operating at 6.78 MHz and the other at 27.12 MHz.
Aldhaher, S, Mitcheson, PD, Yates, DC
core +1 more source
Utility harmonic impedance estimation based on time series clustering and improved Pettitt method
Utility harmonic impedance estimation is critical for power quality assessment and improvement. Noninvasive methods without injecting harmonics are widely adopted to estimate utility harmonic impedance using natural load variations.
Wentao Li +5 more
doaj +1 more source
Utility harmonic impedance is an important parameter for harmonic mitigation. In this paper, a method for utility harmonic impedance estimation method based on constrained independent component analysis is proposed.
Xianyong Xiao +4 more
doaj +1 more source
The brushless doubly fed machine (BDFM) drive system based on a fractional unidirectional converter is a promising low-cost variable-speed drive system, which shows great potential in applications of driving fans and pumps.
Zhenping Li +3 more
doaj +1 more source
Wide-Band Harmonic Impedance Measurement Device for Wind Grid Based on Cascaded H-Bridge Converter
In wind power generation, the coupling of the wind farm power pooling system with the grid may cause high frequency resonance problems and affect the power quality of the grid.
Yongjun YU +6 more
doaj +1 more source
This paper proposes a harmonic compensation control with disturbance rejection function for a standalone inverter. Due to the LC type three-phase three-leg inverter is connected to nonlinear loads, low-order harmonic components appears in the inverter ...
Hui Li, Yue Qu, Junwei Lu, Shuang Li
doaj +1 more source
On the determination of the boundary impedance from the far field pattern
We consider the Helmholtz equation in the half space and suggest two methods for determining the boundary impedance from knowledge of the far field pattern of the time-harmonic incident wave.
Godin, Yuri A., Vainberg, Boris
core +1 more source
Wind turbine filter and reactive power compensation devices lead to the harmonic impedance of wind farm is not much larger than that of the utility, so the influence by the wind farm harmonic impedance can not be neglected while assessing the harmonic ...
Chen Tiantian +4 more
doaj +1 more source
Background: Grid-tied inverters play an efficient role in the integration of renewable energy resources with utility grids. Motivation: However, the interconnection between power converters and the grid has been seen to be responsible for various ...
Tila Muhammad +6 more
doaj +1 more source
In a microgrid system where multiple virtual synchronous generators (VSGs) are interconnected through high impedance cables, the total output negative sequence and harmonic current of multiple VSGs cannot be coordinated based on the capacity of each ...
Luyao Xie +4 more
doaj +1 more source