Results 41 to 50 of about 72,328 (282)
Harmonic state estimation based on graph signal processing
This paper presents a novel harmonic state estimation (HSE) methodology based on graph signal processing. The proposed approach can perform HSE without calculating harmonic impedance. The proposed methodology involves graph signal theory for constructing
Ying Wang +5 more
doaj +1 more source
Optimal design of single-tuned passive filters using response surface methodology [PDF]
This paper presents an approach based on Response Surface Methodology (RSM) to find the optimal parameters of the single-tuned passive filters for harmonic mitigation.
Abdel Aleem, SHE +4 more
core +1 more source
The paper reports an experimental non-linear load evaluation regarding current harmonics sensitivity to supply voltage harmonics. A base for the model is proposed relying on the time-domain waveform variations, rather than impedance or conductance ...
Kamran Daniel +5 more
doaj +1 more source
Design and implementation of a modified fourier analysis harmonic current computation technique for power active filters using DSPs [PDF]
The design and implementation of a harmonic current computation technique based on a modified Fourier analysis, suitable for active power filters incorporating DSPs is presented.
Akagi +25 more
core +1 more source
Measuring the leakage current and voltage of an insulator is widely used to calculate indices for the pollution estimation of overhead line insulator strings.
Rodrigo J. Villalobos +5 more
doaj +1 more source
A 300-800MHz Tunable Filter and Linearized LNA applied in a Low-Noise Harmonic-Rejection RF-Sampling Receiver [PDF]
A multiband flexible RF-sampling receiver aimed at software-defined radio is presented. The wideband RF sampling function is enabled by a recently proposed discrete-time mixing downconverter. This work exploits a voltage-sensing LNA preceded by a tunable
Klumperink, Eric A.M. +3 more
core +3 more sources
Frequency Dependent Specific Heat from Thermal Effusion in Spherical Geometry [PDF]
We present a novel method of measuring the frequency dependent specific heat at the glass transition applied to 5-polyphenyl-4-ether. The method employs thermal waves effusing radially out from the surface of a spherical thermistor that acts as both a ...
Bo Jakobsen +6 more
core +2 more sources
Adaptive PI + VPI Harmonic Current Compensation Strategy under Weak Grid Conditions
With the increase of the penetration rate of renewable energy power generation in the power system, the power grid gradually tends to be weak. Under the scenario of nonlinear load connecting to weak power grid, the grid-side voltage will produce ...
Lili Zhou, Wei Han, Jia Qi, Zhen Zhou
doaj +1 more source
Stability analysis of power-converter-based ac systems poses serious challenges not only because of the nonlinear nature of power converters, but also because linearization is not generally applied around a steady-state operating point, as in the dc case,
Valerio Salis +3 more
semanticscholar +1 more source
Islanding detection method for multi‐terminal renewable power DC distribution system
Most of the traditional islanding detection methods are designed for renewable sources in AC systems and cannot be directly applied in multi‐terminal DC renewable power distribution systems.
Jia Ke +5 more
doaj +1 more source