Results 171 to 180 of about 1,205,170 (259)

Vision and implementation for the first U.S. carbon ion therapy center part II: Design philosophy and clinical implementation

open access: yesJournal of Applied Clinical Medical Physics, Volume 27, Issue 11, November 2026.
Abstract The anticipated clinical demand for carbon ion radiotherapy (CIRT) in the United States is expected to include a substantial proportion of clinically complex disease sites that require accurate, highly conformal, and adaptive treatment. These clinical needs, together with the unique physical and biological characteristics of carbon ion beams ...
Xiaoying Liang, Chris J Beltran
wiley   +1 more source

Geometric and dosimetric effects of an automated clustering and plan optimization pipeline for multiple brain metastasis radiosurgery

open access: yesJournal of Applied Clinical Medical Physics, Volume 27, Issue 11, November 2026.
Abstract Background Treating multiple brain metastases simultaneously with single‐isocenter multi‐target (SIMT) stereotactic radiosurgery (SRS) can streamline treatment planning and delivery. However, it can also result in targets at large distances from the isocenter, increasing sensitivity to rotational setup errors and requiring wider collimator ...
Adam D. Yock   +4 more
wiley   +1 more source

Multi‐system evaluation of baseline‐referenced gray scale CNR profile deviation for phantom‐based ultrasound quality assurance

open access: yesJournal of Applied Clinical Medical Physics, Volume 27, Issue 11, November 2026.
Abstract Background Phantom‐based ultrasound quality assurance (QA) commonly incorporates qualitative image assessment, whereas robust baseline‐referenced quantitative indicators for routine monitoring across multiple systems remain limited. Purpose To investigate whether controlled transducer surface acoustic shielding produces measurable baseline ...
Ji‐Hye Kim, Yeong‐Cheol Heo
wiley   +1 more source

Technical development and implementation of 3D‐QALAS on a 1.5T MR‐Linac for the brain: A prospective R‐IDEAL stage 0/1 technology development report

open access: yesJournal of Applied Clinical Medical Physics, Volume 27, Issue 11, November 2026.
Abstract Background Quantitative relaxometry of the brain on the integrated MRI / linear accelerator (MR‐Linac) at high isotropic reconstructed resolution is currently limited due to prohibitively long scan times and limited field‐of‐views. Purpose The purpose of this study was to assess the technical feasibility of the 3D‐QALAS technique on the 1.5T ...
Lucas McCullum   +8 more
wiley   +1 more source

Automated verification of source dwell position in lunar ovoid applicators

open access: yesJournal of Applied Clinical Medical Physics, Volume 27, Issue 11, November 2026.
Abstract Background Accurate reconstruction of the source dwell positions in high‐dose‐rate (HDR) brachytherapy is essential for treatment quality. The Venezia™ gynaecological applicator, with its lunar‐shaped ovoids, poses challenges because conventional dummy markers do not match the actual source path, introducing systematic uncertainties.
Miquel Gubau‐Besalú   +6 more
wiley   +1 more source

Linac performance benchmarking: Feasibility of a web‐based tool for comparison of local machine performance check (MPC) results with the global community

open access: yesJournal of Applied Clinical Medical Physics, Volume 27, Issue 11, November 2026.
Abstract Background Varian machine performance check (MPC) is a manufacturer integrated quality control system included as standard for TrueBeam and Halcyon linear accelerators (linacs) to assess performance using a broad range of geometric and beam tests.
Lauren May   +12 more
wiley   +1 more source

A multicenter end‐to‐end postal audit of skin markerless surface‐guided radiation therapy

open access: yesJournal of Applied Clinical Medical Physics, Volume 27, Issue 11, November 2026.
Abstract Background Surface‐guided radiation therapy (SGRT) enables skin markerless positioning, but its accuracy may depend on the reference surface, hardware configuration, commissioning, and institutional workflow. Two reference surfaces are commonly used: a DICOM reference generated from planning CT images and an SGRT reference acquired in the ...
Masahide Saito   +20 more
wiley   +1 more source

Retrospective analysis of machine service logs and EPID‐based linac QA to investigate the effects of machine maintenance and calibration events on beam characteristics: A multi‐institutional study

open access: yesJournal of Applied Clinical Medical Physics, Volume 27, Issue 11, November 2026.
Abstract Background Electronic Portal Imaging Devices (EPIDs) are widely used for LINAC quality assurance (QA) and underpin many manufacturer integrated quality control (MIQC) tools, yet the practical impact of routine linac service and calibration events on EPID‐derived beam characteristics remains under‐described. The Automated Quality Assurance (AQA)
John DeMarco   +13 more
wiley   +1 more source

Home - About - Disclaimer - Privacy