Radiotherapy as a metastasis directed therapy for liver oligometastases - comparative analysis between CT-guided interstitial HDR brachytherapy and two SBRT modalities performed on double-layer and single layer LINACs. [PDF]
Bilski M +11 more
europepmc +1 more source
Development, implementation, and associated challenges of a new HDR brachytherapy program. [PDF]
Scanderbeg DJ +4 more
europepmc +1 more source
Inversion-recovery ultrashort-echo-time (IR-UTE) MRI-based detection of radiation dose heterogeneity in gynecologic cancer patients treated with HDR brachytherapy. [PDF]
Sheikh K +9 more
europepmc +1 more source
The effect of vaginal cylinder inhomogeneity on the HDR brachytherapy dose calculations using Monte Carlo simulations. [PDF]
Meftahi M, Song WY.
europepmc +1 more source
Related searches:
Brachytherapy has become an essential pillar in all-stages of localized prostate cancer, where dose escalation has been demonstrated to improve outcome. HDR brachytherapy has evolved over the decades to be administered in 1-2 fractions. As either monotherapy or in combination with external beam, it offers many advantages over other treatment ...
Juanita, Crook +2 more
openaire +2 more sources
CT-Based Interstitial HDR Brachytherapy
Strahlentherapie und Onkologie, 1999Development, application and evaluation of a CT-guided implantation technique and a fully CT-based treatment planning procedure for brachytherapy.A brachytherapy procedure based on CT-guided implantation technique and CT-based treatment planning has been developed and clinical evaluated.
C, Kolotas, D, Baltas, N, Zamboglou
openaire +2 more sources
HDR Versus LDR Gynecological Brachytherapy Revisited
Medical Dosimetry, 1993Despite the obvious breakthrough of high dose-rate (HDR) afterloading systems on the gynecological brachytherapy market, questions still remain regarding the transfer of available expertise gained throughout the last 80 years with low dose-rate (LDR) radium and cesium, especially regarding the conversion of LDR total dose into equivalent HDR dose per ...
P, Scalliet, A, Gerbaulet, B, Dubray
openaire +2 more sources
Optimisation in HDR brachytherapy
Reports of Practical Oncology, 1997New HDR machines supplied with stepping source systems give us an additional opportunity to optimise source distribution by modeling source dwell time. Different optimization algorithms are implemented in the commercial planning systems connected with HDR machines.
R. Kabacińska +3 more
openaire +1 more source
118CT based interstitial HDR brachytherapy
Radiotherapy and Oncology, 1998Development, application and evaluation of a CT-guided implantation technique and a fully CT-based treatment planning procedure for brachytherapy.
Christos Kolotas +4 more
openaire +1 more source