Results 131 to 140 of about 4,664 (185)
Some of the next articles are maybe not open access.

On-line implant reconstruction in HDR brachytherapy

Radiotherapy and Oncology, 2006
To evaluate the accuracy of on-line planning in an Integrated Brachytherapy Unit (IBU) using dedicated image distortion correction algorithms, correcting the geometric distortion and magnetic distortion separately, and to determine the effect of the reconstruction accuracy on clinical treatment plans in terms of deviations in treatment time and dose ...
Kolkman - Deurloo, Inger-karine   +2 more
openaire   +3 more sources

Practical considerations for prostate HDR brachytherapy

Brachytherapy, 2010
A process for prostate high-dose-rate (HDR) brachytherapy was developed and implemented successfully in the community hospital setting. The practical aspects of the program are reviewed and may serve as a foundation for clinics interested in offering this clinical service.A generic needle distribution geometry was established to accommodate target ...
openaire   +2 more sources

34. Optimization in HDR gynecological brachytherapy

Physica Medica, 2017
Introduction The distal vagina HDR brachytherapy is the final treatment of cervical cancer, as a complementary treatment to surgery and/or external radiation therapy. The goal of this study was to evaluate the coverage of the Clinical Target Volume and the maximum dose received by the Organs at Risk, related to the rectal volume and the optimization ...
M. Vande Woestyne   +4 more
openaire   +1 more source

Anatomy based inverse planning in HDR prostate brachytherapy

Radiotherapy and Oncology, 2004
The purpose of this study is to evaluate anatomy based inverse planning as implemented in PLATO BPS 14.2 for planning of HDR prostate implants. Six patients were analysed. The dose distributions were optimized using geometric optimization followed by graphical optimization (GO), anatomy based inverse planning or standard inverse optimization (SIO ...
Kolkman- Deurloo, IKK   +3 more
openaire   +2 more sources

WE-F-BRD-01: HDR Brachytherapy II: Integrating Imaging with HDR

Medical Physics, 2014
In recent years, with the advent of high/pulsed dose rate afterloading technology, advanced treatment planning systems, CT/MRI compatible applicators, and advanced imaging platforms, image-guided adaptive brachytherapy treatments (IGABT) have started to play an ever increasing role in modern radiation therapy.
O Craciunescu, D Todor, A de Leeuw
openaire   +1 more source

Optimization of HDR Brachytherapy Treatment Plans

2007
Purpose: Effective cancer brachytherapy requires a treatment plan that delivers high dose to tumor while minimizing dose to critical normal tissue. Current planning systems generate accurately physical dose distributions but do not take biological effects into account.
James C. H. Chu   +5 more
openaire   +1 more source

Monte Carlo dosimetry in HDR brachytherapy

AIP Conference Proceedings, 2000
A Monte Carlo simulation of an encapsulated 192Ir source for high dose rate (HDR) prostate brachytherapy is presented. Basic dosimetric quantities related to this source are derived from the simulation data following the AAPM Task Group 43 formalism, including dose rate constant, source kerma strength, anisotropy function and radial dose function. Dose
openaire   +1 more source

Attenuation of intracavitary applicators in ‐HDR brachytherapy

Medical Physics, 2004
Unlike the penetrating monoenergetic 662 keV gamma rays emitted by LDR sources, the spectrum of used in HDR brachytherapy contains low‐energy components. Since these are selectively absorbed by the high‐atomic number materials of which intracavitary applicators are made, the traditional neglect of applicator attenuation can lead to appreciable dose ...
Sung‐Joon Ye   +5 more
openaire   +1 more source

Results of HDR Prostate Brachytherapy Treatments

2013
Most of the publications deal with retrospective monoinstitutional results or with the statistical analysis of multi-institutional data pools. Although results of prospective nonrandomized studies or retrospective data analysis may be influenced by potential selection bias and inconsistent data analysis, careful presentation can help to understand ...
openaire   +1 more source