Results 51 to 60 of about 51,158 (208)
BACKGROUND: This study compares low dose rate (LDR) and high dose rate (HDR) intracavitary brachytherapy (ICBT) in the treatment of cervical cancer treated at a tertiary care cancer centre in North India.
Purnima Thakur +5 more
doaj +1 more source
Abstract Background Biopsy‐level dose interpretation after high‐dose‐rate prostate brachytherapy is limited by localization uncertainty, and separate voxelwise Monte Carlo summaries do not explicitly account for the axial spatial correlation present along a biopsy core.
Matthew Muscat +4 more
wiley +1 more source
Spot size reduction and minibeam creation in a proton PBS nozzle using multipole permanent magnets
Abstract Background Smaller spot sizes in pencil beam scanning (PBS) nozzles are generally desired to allow more conformal treatments and to spare normal tissue and organs at risk. The production of small diameter proton beams, especially proton minibeams, is challenging because long drift spaces in standard PBS nozzles exacerbate effects of MCS and ...
Grant A. McAuley
wiley +1 more source
High-dose-rate brachytherapy in the treatment of skin Kaposi sarcoma
Purpose : The aim of the study is to review our experience in treatment of Kaposi sarcoma (KS) lesions with high-dose-rate (HDR) brachytherapy. Material and methods : We present five new KS lesions (three patients) that were treated in our hospital ...
María Ángeles González Ruiz +10 more
doaj +1 more source
HDR Brachytherapy in the Management of High-Risk Prostate Cancer [PDF]
High-dose-rate (HDR) brachytherapy is used with increasing frequency for the treatment of prostate cancer. It is a technique which allows delivery of large individual fractions to the prostate without exposing adjacent normal tissues to unacceptable toxicity. This approach is particularly favourable in prostate cancer where tumours are highly sensitive
Susan Masson, Raj Persad, Amit Bahl
openaire +3 more sources
Seeing radiation: Applications of an imaging survey meter in radiation oncology
Abstract Background and purpose Radiation shielding surveys require location and evaluation of radiation hotspots in shielding barriers. This process is normally done by using a conventional survey meter and slowly moving the survey meter manually across the face of the barrier.
Patrick N. McDermott +8 more
wiley +1 more source
Mathematical Optimization of HDR Brachytherapy
One out of eight deaths throughout the world is due to cancer. Developing new treatments and improving existing treatments is hence of major importance.
openaire +4 more sources
Background This study assesses recent treatments for locally advanced non-small cell lung cancer (LA-NSCLC) ineligible for surgery, comparing high-dose-rate (HDR) brachytherapy with conventional low linear energy transfer (LET) hypofractionated ...
Mingyu Tan +3 more
doaj +1 more source
Summary of HDR prostate brachytherapy in vivo dosimetry data for per plan and per needle ...
Mason, J (via Mendeley Data) +1 more
core +1 more source
Abstract Background Beam diagnostic systems are essential for the development and quality assurance of ultra‐high dose rate (UHDR) radiation sources to enable reliable delivery of FLASH radiotherapy (RT). Critically, suitable beam diagnostic systems for electron FLASH sources are lacking.
Alan Lopez +5 more
wiley +1 more source

