Results 51 to 60 of about 51,158 (208)

Comparative analysis of LDR and HDR intracavitary brachytherapy in cervical cancer: the critical role of overall treatment time — a decade of experience

open access: yesReports of Practical Oncology and Radiotherapy
BACKGROUND: This study compares low dose rate (LDR) and high dose rate (HDR) intracavitary brachytherapy (ICBT) in the treatment of cervical cancer treated at a tertiary care cancer centre in North India.
Purnima Thakur   +5 more
doaj   +1 more source

Gaussian process regression of HDR prostate biopsy dose for improved modelling of localization‐induced uncertainty

open access: yesMedical Physics, Volume 53, Issue 11, November 2026.
Abstract Background Biopsy‐level dose interpretation after high‐dose‐rate prostate brachytherapy is limited by localization uncertainty, and separate voxelwise Monte Carlo summaries do not explicitly account for the axial spatial correlation present along a biopsy core.
Matthew Muscat   +4 more
wiley   +1 more source

Spot size reduction and minibeam creation in a proton PBS nozzle using multipole permanent magnets

open access: yesMedical Physics, Volume 53, Issue 11, November 2026.
Abstract Background Smaller spot sizes in pencil beam scanning (PBS) nozzles are generally desired to allow more conformal treatments and to spare normal tissue and organs at risk. The production of small diameter proton beams, especially proton minibeams, is challenging because long drift spaces in standard PBS nozzles exacerbate effects of MCS and ...
Grant A. McAuley
wiley   +1 more source

High-dose-rate brachytherapy in the treatment of skin Kaposi sarcoma

open access: yesJournal of Contemporary Brachytherapy, 2017
Purpose : The aim of the study is to review our experience in treatment of Kaposi sarcoma (KS) lesions with high-dose-rate (HDR) brachytherapy. Material and methods : We present five new KS lesions (three patients) that were treated in our hospital ...
María Ángeles González Ruiz   +10 more
doaj   +1 more source

HDR Brachytherapy in the Management of High-Risk Prostate Cancer [PDF]

open access: yesAdvances in Urology, 2012
High-dose-rate (HDR) brachytherapy is used with increasing frequency for the treatment of prostate cancer. It is a technique which allows delivery of large individual fractions to the prostate without exposing adjacent normal tissues to unacceptable toxicity. This approach is particularly favourable in prostate cancer where tumours are highly sensitive
Susan Masson, Raj Persad, Amit Bahl
openaire   +3 more sources

Seeing radiation: Applications of an imaging survey meter in radiation oncology

open access: yesJournal of Applied Clinical Medical Physics, Volume 27, Issue 10, October 2026.
Abstract Background and purpose Radiation shielding surveys require location and evaluation of radiation hotspots in shielding barriers. This process is normally done by using a conventional survey meter and slowly moving the survey meter manually across the face of the barrier.
Patrick N. McDermott   +8 more
wiley   +1 more source

Mathematical Optimization of HDR Brachytherapy

open access: yes, 2013
One out of eight deaths throughout the world is due to cancer. Developing new treatments and improving existing treatments is hence of major importance.
openaire   +4 more sources

Innovations in modern low-LET radiotherapy regimens for locally advanced non-small cell lung cancer: a meta-analysis and systematic review of high-dose-rate brachytherapy, stereotactic body radiotherapy, and hypofractionated proton therapy

open access: yesBMC Cancer
Background This study assesses recent treatments for locally advanced non-small cell lung cancer (LA-NSCLC) ineligible for surgery, comparing high-dose-rate (HDR) brachytherapy with conventional low linear energy transfer (LET) hypofractionated ...
Mingyu Tan   +3 more
doaj   +1 more source

Data for: Error detection thresholds for routine real time in vivo dosimetry in HDR prostate brachytherapy

open access: yes, 2021
Summary of HDR prostate brachytherapy in vivo dosimetry data for per plan and per needle ...
Mason, J (via Mendeley Data)   +1 more
core   +1 more source

Evaluation of a Faraday cup‐style detector as a beam diagnostic system for ultra‐high dose rate (FLASH) electron beams

open access: yesJournal of Applied Clinical Medical Physics, Volume 27, Issue 10, October 2026.
Abstract Background Beam diagnostic systems are essential for the development and quality assurance of ultra‐high dose rate (UHDR) radiation sources to enable reliable delivery of FLASH radiotherapy (RT). Critically, suitable beam diagnostic systems for electron FLASH sources are lacking.
Alan Lopez   +5 more
wiley   +1 more source

Home - About - Disclaimer - Privacy