Results 61 to 70 of about 375,783 (317)

Implementation of needle‐tracking technology for real‐time transrectal ultrasound‐guided interstitial gynecological HDR brachytherapy: A feasibility study

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose To investigate the feasibility of adapting a commercial prostate biopsy system for transrectal ultrasound (TRUS)‐guided hybrid gynecological (GYN) high‐dose‐rate (HDR) brachytherapy (BT). Leveraging 3D‐TRUS and MR image fusion, the prototype system aims to improve real‐time needle placement accuracy.
Lindsey H. Bloom   +8 more
wiley   +1 more source

Accounting for TLD response to CBCT protocols in external beam radiotherapy dose monitoring

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose LiF thermoluminescent dosimeters (TLDs) are commonly used in radiation therapy to verify the delivered dose. Examples include dose verification for complicated treatment setups or cardiovascular implantable electronic devices (CIEDs). TLDs may be present for both the pre‐treatment imaging kilovoltage (kV) beam and the megavoltage (MV ...
Andrew J. White   +5 more
wiley   +1 more source

Successful heart transplantation after 4 years of bridging with HeartWare HVAD for left ventricular noncompaction in an 11-year-old boy with prohibitively high pulmonary vascular resistance

open access: yesAnnals of Pediatric Cardiology
End-stage heart failure due to left ventricular noncompaction (LVNC) poses unique challenges for ventricular assist device implantation, like inflow cannula obstruction due to trabeculations. We report a case of an 11-year-old boy with LVNC who underwent
Komarakshi R. Balakrishnan   +4 more
doaj   +1 more source

Hemostatic complications associated with ventricular assist devices

open access: yesResearch and Practice in Thrombosis and Haemostasis, 2019
Hemostatic complications are common in patients with ventricular assist devices. The pathophysiologic mechanisms that lead to dysregulated hemostasis involve complex interactions between device surface, sheer stress, and blood flow. These factors lead to
Talal Hilal   +2 more
doaj   +1 more source

Effectiveness of a Telephone‐Delivered Walk With Ease Program on Arthritis‐Related Symptoms, Function, and Activity: A Randomized Trial

open access: yesArthritis Care &Research, EarlyView.
Objective Walk With Ease (WWE) is a six‐week arthritis‐appropriate evidence‐based physical activity program traditionally offered in a face‐to‐face format. Because many populations encounter participation barriers to in‐person programs, WWE was modified for telephone delivery (WWE‐T).
Christine A. Pellegrini   +5 more
wiley   +1 more source

New pharmacological and technological management strategies in heart failure

open access: yesVascular Health and Risk Management, 2017
Sunit-Preet Chaudhry,1 Garrick C Stewart2 1Division of Cardiology, St Vincent Indianapolis, Indianapolis, IN, 2Division of Cardiovascular Medicine, Center for Advanced Heart Disease, Brigham and Women’s Hospital, Boston, MA, USA Abstract ...
Chaudhry SP, Stewart GC
doaj  

At the Heart of Innovation: Jefferson’s Heart Transplant Program [PDF]

open access: yes, 2017
Jefferson’s Heart Transplant Program reactivated this year with a new, system-wide approach to heart failure that makes innovative, evidence-based, comprehensive care more accessible to patients throughout the Delaware Valley.

core   +1 more source

Effects of Dalcroze Eurhythmics Exercise Versus Multicomponent Exercise on Physical and Cognitive Function, and Falls in Older Adults: The EPHYCOS Randomized Controlled Trial

open access: yesAdvanced Biology, EarlyView.
In this randomized clinical trial conducted among 142 community‐dwelling older adults at high risk for falls over 12 months, a Dalcroze Eurhythmics exercise intervention (once weekly, group‐based) improved a variety of physical and cognitive/executive function outcomes compared with a multicomponent exercise intervention (twice weekly, group‐ and home ...
Mélany Hars   +7 more
wiley   +1 more source

A Cybersecurity Guide for Using Fitness Devices [PDF]

open access: yesarXiv, 2021
The popularity of wearable devices is growing exponentially, with consumers using these for a variety of services. Fitness devices are currently offering new services such as shopping or buying train tickets using contactless payment. In addition, fitness devices are collecting a number of personal information such as body temperature, pulse rate, food
arxiv  

Current and Future Cornea Chip Models for Advancing Ophthalmic Research and Therapeutics

open access: yesAdvanced Biology, EarlyView.
This review analyzes cornea chip technology as an innovative solution to corneal blindness and tissue scarcity. The examination encompasses recent developments in biomaterial design and fabrication methods replicating corneal architecture, highlighting applications in drug screening and disease modeling while addressing key challenges in mimicking ...
Minju Kim   +3 more
wiley   +1 more source