Post‐Market Analysis of the Xenios Console With the Xlung Tubing Kit 230 for Extracorporeal Membrane Oxygenation After Cardiac Surgery

open access: yesArtificial Organs, EarlyView.
This study is a comprehensive post‐market analysis of the Xenios console and XLung kit 230 preconfigured ECMO tubing set in post‐cardiotomy applications. The performance of this device was evaluated and demonstrated in all key clinical areas, with an adequate safety profile.
Luca Conci   +9 more
wiley   +1 more source

An Optimized Multi‐Stage Drainage Cannula Design for Venoarterial Extracorporeal Membrane Oxygenation

open access: yesArtificial Organs, EarlyView.
This study utilized an extensive optimization involving n = 540 design of experiments to produce a superior drainage cannula design. Compared to the clinically used Maquet model, our optimized design demonstrated reduced blood stagnation volumes, increased cannula tip velocities, and higher upper body drainage, potentially minimizing risk of thrombosis
Avishka Wickramarachchi   +3 more
wiley   +1 more source

Prescription of the first prosthesis and later use in children with congenital unilateral upper limb deficiency: A systematic review [PDF]

open access: yes, 2006
Background: The prosthetic rejection rates in children with an upper limb transversal reduction deficiency are considerable. It is unclear whether the timing of the first prescription of the prosthesis contributes to the rejection rates.
Maathuis, C.G.B.   +13 more
core   +2 more sources

Geometry‐Related Technical Complications After LVAD Implantation: Impact on Device Dysfunction and Clinical Outcomes

open access: yesArtificial Organs, EarlyView.
Preventable geometric failure modes, such as outflow graft kinking and inflow malposition, frequently cause HeartMate 3 dysfunction. This study identifies these complications as key drivers of device‐related morbidity, highlighting the importance of optimized surgical positioning to ensure long‐term device performance and improved clinical outcomes ...
Ali Saad Merzah   +17 more
wiley   +1 more source

Early Multicenter Outcomes of Dedicated Transcatheter Aortic Valve Replacement for Left Ventricular Assist Device‐Associated Pure Aortic Regurgitation

open access: yesArtificial Organs, EarlyView.
LVAD‐associated aortic regurgitation impairs circulatory support, with limited surgical and off‐label options. In a multicenter registry (n = 30), the AR‐dedicated JenaValve Trilogy TAVR eliminated AR, achieving 96.7% (29/30) technical success and 93.3% (28/30) device success (VARC‐3), with 3.3% (1/30) 30‐day mortality.
Hristian Hinkov   +13 more
wiley   +1 more source

A guide to the ecological limitations of phage therapy of bacterial biofilms: Is what's best for the phage best for the physician?

open access: yesThe FEBS Journal, EarlyView.
Bacteriophages—viruses that kill bacteria—are promising weapons against bacterial biofilms: sessile communities notoriously resistant to antibiotics. Yet phages evolved not so much to eradicate bacteria as to obtain new bacteria to infect. That goal, however, may conflict with the physician's objective of complete bacterial clearance.
Stephen T. Abedon
wiley   +1 more source

Can Artificial Intelligence Be Utilised to Develop Point‐of‐Care Endodontic Microbiological Technologies?

open access: yesInternational Endodontic Journal, EarlyView.
ABSTRACT Background Primary or persistent endodontic disease is caused by microbial biofilms that irritate the pulp and periapical tissues. Extensive microbiological analyses of these biofilms and their constituent pathogens have revealed their diversity and complexity.
Ashraf F. Fouad
wiley   +1 more source

Refining Residual Ischemic Stroke Risk in Anticoagulated Atrial Fibrillation Using Index Outpatient LA Diameter: The CHA2DS2‐VALa Score

open access: yesJournal of Cardiovascular Electrophysiology, EarlyView.
In anticoagulated atrial fibrillation, residual ischemic stroke risk persists despite guideline‐directed therapy. In this single‐center cohort, an enlarged index outpatient left atrial diameter independently predicted stroke and improved risk stratification when added to CHA2DS2‐VA (CHA2DS2‐VALa), supporting a simple, clinically implementable ...
Sefa Erdi Ömür   +7 more
wiley   +1 more source

Characterization of the Effective Orifice Areas of Mitral Prosthetic Heart Valves: An In Vitro Study

open access: yes, 2017
Objectives: Reference values of hemodynamic parameters for the assessment of prosthetic heart valves are necessary and ideally need to be provided by entities independent of valve manufacturers.
GRIEVE, Stuart Mickael   +4 more
core   +1 more source

Bioprosthetic or mechanical heart valves: prosthesis choice for borderline patients?-Results from 9,616 cases recorded in Polish national cardiac surgery registry. [PDF]

open access: yesJ Thorac Dis, 2020
Bartus K   +17 more
europepmc   +1 more source

Home - About - Disclaimer - Privacy