Results 21 to 30 of about 106,787 (169)

Upgrading the hot water supply system as a way to save energy [PDF]

open access: yesE3S Web of Conferences, 2021
The efficiency of works on replacement of steel pipelines of hot water supply of Kazan with pipes from polymer materials was considered. Due to the high corrosive activity of water, the service life of hot water pipelines does not exceed 8-10 years.
Akhmerova Guzel   +4 more
doaj   +1 more source

Model of Electric and Heat Balance of Biogas Station

open access: yesAdvances in Electrical and Electronic Engineering, 2016
This paper deals with the model of a biogas station. The introduction provides a description of principle employed in this model. The model works with data reflecting the quantity and type of the input biomass to determine the potential energy and offer ...
Jiri Jansa, Zdenek Hradilek
doaj   +1 more source

ON THE ISSUE OF STUDYING THE INFLUENCE OF STRUCTURAL FEATURES OF DOUBLE-GLAZED WINDOWS ON THE TOTAL HEAT LOSS OF BUILDINGS

open access: yesШәкәрім университетінің хабаршысы: Техника ғылымдар
Issues of the effective functioning of life support systems are always relevant and are reflected in the works of leading scientists. Consideration of the possibilities of reducing heat loss at all stages of transportation and operation is a promising ...
M. V. Ermolenko   +4 more
doaj   +1 more source

Canola seeds losses during harvest using grain combine harvester as a function of thermal properties of canola unbroken pod [PDF]

open access: yesمجله پژوهش‌های علوم و صنایع غذایی ایران, 2017
The present study investigated the thermal properties of canola pods (thermal conductivity, specific heat, and thermal diffusivity), canola losses (natural losses, platform losses, and total combine harvester losses), and unbroken pods in three common ...
احسان قجرجزی   +2 more
doaj   +1 more source

Investigation on Relative Heat Losses and Gains of Heating and Cooling Networks

open access: yesEnvironmental and Climate Technologies, 2021
The integration of district heating (DH) and cooling (DC) in the sustainable energy system of the future requires a significant reduction in operating temperatures. Supply temperatures below 70 °C are required for new 4th Generation DH. Main benefits are
Madan Violeta, Weidlich Ingo
doaj   +1 more source

HEAT LOSS DURING ANAESTHESIA

open access: yesBritish Journal of Anaesthesia, 1978
The superficial and deep body temperatures of 23 patients were studied during prolonged anaesthesia for microscopic surgery of the fallopian tubes. The patients were divided randomly into three groups, receiving either halothane 0.5%, halothane 1% or low-dose fentanyl as a supplement to nitrous oxide, oxygen and myoneural block.
A, Holdcroft, G M, Hall
openaire   +2 more sources

New Dimensionless Correlations for the Evaluation of the Thermal Resistances of a District Heating Twin Pipe System

open access: yesApplied Sciences, 2021
The heat losses from pre-insulated double-pipe district heating (DH) systems buried in a homogeneous soil are studied numerically. The study is conducted using the diameter of the pipes and their distance, the size of the insulation, the thermal ...
Massimo Corcione   +3 more
doaj   +1 more source

Numerical analysis of the effect of freezing ground in the laying zone pads on heat loss of channelless pipelines laid out without canals [PDF]

open access: yesИнженерно-строительный журнал, 2013
The results of mathematical modeling of heating mains laid out without canals, as well as numerical analysis of their heat losses in the presence of ground freezing in the area of installation are presented.
V.Yu. Polovnikov, V.A. Huzeev
doaj  

Experimental Assessment of the Thermal Conductivity of Basalt Fibres at High Temperatures

open access: yesEnergies, 2022
This paper investigates fibrous thermal insulation materials of various densities to assess the change in their thermophysical properties at high temperatures. The thermal conductivity of fibrous thermal insulation materials is discussed as a function of
Yuri Vankov   +6 more
doaj   +1 more source

Thermal Transmittance in Roof–Wall Structural Junction Areas Insulated with a Hemp–Lime Mixture

open access: yesEnergies
The junction between the roof and the external wall is a sensitive area within the building envelope; here, increased heat flow often takes place.
Magdalena Grudzińska   +3 more
doaj   +1 more source