Persistent contamination of heater–cooler units for extracorporeal circulation cured by chlorhexidine–alcohol in water tanks [PDF]

open access: yesJournal of Hospital Infection, 2018
Recently, surgical site infections due to non-tuberculous mycobacteria (NTM) have been linked to heater-cooler unit contamination. The European Centre for Disease Prevention and Control and manufacturers now recommend the use of hydrogen peroxide in filtered water to fill heater-cooler unit tanks. After implementation of these measures in our hospital,
Sara Romano-Bertrand, E Jumas-Bilak
exaly   +5 more sources

The Global Outbreak of M. chimaera Infection Following Cardiac Surgery: Another Piece of the Puzzle [PDF]

open access: yesPathogens
Invasive cases of Mycobacterium chimaera have been found in Europe, and beyond, and have been associated with the use of heater–cooler units necessary to regulate the temperature of blood in extracorporeal circulation during cardiac surgery, mostly due ...
Savina Ditommaso   +5 more
doaj   +2 more sources

Image dataset of environmental non-tuberculous mycobacteria isolated from heater cooler units water by the new NTM Elite agarMendeley Data [PDF]

open access: yesData in Brief
This article presents an image dataset of non-tuberculous mycobacteria (NTM) isolated from heater-cooler units (HCU) using the recently developed NTM Elite agar (bioMérieux, Marcy-l’Étoile, France).
Monica Giacomuzzi   +4 more
doaj   +2 more sources

The Heater–Cooler Unit—A Conceivable Source of Infection

open access: yesThe Journal of ExtraCorporeal Technology, 2002
Even drinking water is contaminated with pathogenic microorganisms. This does not necessarily pose a risk for healthy individuals, but it may result in serious consequences in people with impaired immune systems. This is particularly valid if drinking water is used for medical purposes.
H.H. Weitkemper   +3 more
openaire   +2 more sources

Biofilm formation by the global outbreak strain of Mycobacterium chimaera results in significantly reduced efficacy of standard disinfectants [PDF]

open access: yesBMC Microbiology
Background In 2013, a global outbreak of Mycobacterium chimaera infections due to contaminated heater-cooler units emerged. This ongoing problem has highlighted the question of whether disinfection recommendations for medical devices containing water ...
Anna Maria Oschmann   +6 more
doaj   +2 more sources

Microbiological problems and biofilms associated with Mycobacterium chimaera in heater–cooler units used for cardiopulmonary bypass [PDF]

open access: yesJournal of Hospital Infection, 2017
The role of heater-cooler units (HCUs) in the transmission of Mycobacterium chimaera during open heart surgery has been recognized since 2013. Subsequent investigations uncovered a remarkable global outbreak reflecting the wide distribution of implicated devices.
Theresa L Lamagni   +2 more
exaly   +3 more sources

Transfer Irreversibilities in the Lenoir Cycle: FTT Design Criteria with ε−NTU [PDF]

open access: yesEntropy
This work extends the steady flow Lenoir cycle within finite-time thermodynamics (FTT) by incorporating heat transfer irreversibilities through the ε−NTU formalism and a non-isentropic expansion modeled via the expander isentropic efficiency ηE.
Ricardo T. Páez-Hernández   +4 more
doaj   +2 more sources

Detection of Mycobacterium chimaera in medical device water samples by customised real time PCR using a InGenius platform [PDF]

open access: yesScientific Reports
Mycobacterium chimaera, belonging to the Mycobacterium avium complex, is an opportunistic environmental mycobacterium which has been isolated from medical device water samples such as Heater Cooler Units (HCU).
Francesco Bisognin   +7 more
doaj   +2 more sources

Study on Calculation Method of Inlet Steam Flow of External Steam Cooler in Feedwater Heating System [PDF]

open access: yesE3S Web of Conferences, 2022
In order to improve the thermal economic performance of coal-fired units in thermal power industry, supercritical units above 600MW generally adopt the method of installing external steam cooler system to improve the utilization of reheat. In view of the
Zhu Lingkai   +7 more
doaj   +1 more source