Results 111 to 120 of about 6,384 (155)
Some of the next articles are maybe not open access.
Evaluation of the Utility of the HemoCue 301 Haemoglobinometer for Blood Donor Screening
Vox Sanguinis, 2007Background and Objectives Reliable blood donor screening requires more accurate measure of haemoglobin (Hb) than by either copper sulphate or the haemoglobin colour scale. The HemoCue haemoglobinometer has established a method for this, but it is considerably more expensive; a modified version (HemoCue 301) has now been developed with a cheaper ...
S M Lewis
exaly +3 more sources
The Use of a Hemocue Blood Glucose Analyser in a Neonatal Unit
Annals of Clinical Biochemistry: International Journal of Laboratory Medicine, 1997Near patient testing for glucose is now a widely accepted procedure in hospital wards and clinics. However, in a neonatal ward where the detection of hypoglycaemia rather than hyperglycaemia is of paramount importance, it is more difficult to find a suitable glucose monitoring instrument. We compared two Hemocue blood glucose analysers (Hemocue Ltd) in
M, Leonard, M, Chessall, D, Manning
openaire +2 more sources
Assessment of the Hemocue-b for measuring hemoglobin in horse blood
Veterinary Anaesthesia and Analgesia, 2003Our purpose was to assess the accuracy and precision of a point of care hemoglobinometer (HemoCue-B hemoglobin photometer) for measuring hemoglobin concentration in horse blood. Samples of jugular venous blood from 12 healthy adult horses were collected in EDTA.
H, Chevalier +4 more
openaire +2 more sources
Blood Loss Estimation During Laparoscopic Myomectomy Using HemoCue®
During laparoscopic myomectomy, it is difficult to determine the actual blood loss volume because physiological saline is used for lavaging to detect the bleeding point or to ensure no active bleeding site. We attempted to estimate blood loss by measuring the waste irrigation fluid's hemoglobin (Hb) concentration using HemoCue (HemoCue, Angelholm ...
Yoichi Shimada +2 more
exaly +4 more sources
Evaluation of the HemoCue Glucose 201 Room Temperature Microcuvettes
Point of Care: The Journal of Near-Patient Testing & Technology, 2007Introduction:A new room-temperature storage cuvette for the portable HemoCue glucose analyzers (HemoCue Inc, Lake Forest, Calif) was evaluated for technical performance by comparing a point-of-care glucose meter (Precision PCx; Abbott Diagnostics, Abbott Park, Ill) and a hexokinase central ...
Aparna Rajadhyaksha +2 more
openaire +1 more source
Accuracy of the HemoCue Portable Glucose Analyzer in a Large Nonhomogeneous Population
Diabetes Technology & Therapeutics, 2001Several studies have reported inconsistent results between HemoCue (HC) whole blood glucose measurements compared to plasma glucose. We selected a large patient population with diverse pathologies and healthy volunteers to evaluate HC. For this comparison, whole blood glucose concentration was measured using HC and referenced to laboratory plasma ...
Marc C. Torjman +4 more
openaire +2 more sources
Hemocue--a new haemoglobinometer in the clinic.
European journal of anaesthesiology, 1991The accuracy of the Hemocue, a portable haemoglobinometer, was tested on 29 patients undergoing open-heart surgery, and the results were compared with the haemoglobin values obtained from the hospital laboratory. Special attention was paid to the lower range of haemoglobin values and the simplicity and speed of operating the meter.
W K, Be, H E, Kerkkamp, L H, Booij
openaire +1 more source
Evaluation of the Hemocue portable hemoglobinometer after major joint arthroplasty
The Journal of Arthroplasty, 2002We evaluated the potential use of the Hemocue (Hemocue AB, Sweden) portable hemoglobinometer on the 1st postoperative evening after major joint arthroplasty. We compared hemoglobinometer values with conventional Coulter counter laboratory analysis in a population of 67 patients. The hemoglobinometer proved practical, economical, and accurate in general,
Marco, Teli, Yeung, Ng, Roland, Ingram
openaire +2 more sources
Predictive Value of HemoCue Capillary Whole Blood Glucose Measurements in Pregnancy
Journal of the Society for Gynecologic Investigation, 1995We determined the ability of capillary whole blood glucose concentrations to predict venous plasma and whole blood glucose levels.During a standard oral glucose tolerance test in 29 pregnant women, paired capillary and venous blood samples were collected for analysis of glucose concentrations by the HemoCue photometer and by central laboratory methods ...
F Y, Teng, O, Punla, B J, Koos
openaire +2 more sources
Accuracy of a Simplified Glucose Measurement Device—The HemoCue Glucose 201RT
Diabetes Technology & Therapeutics, 2015Background: Easily available, accurate glucose recordings are important when screening for and managing people with diabetes. The photometric HemoCue ® (Ängelholm, Sweden) Glucose 201+ system, which delivers lab-comparable glucose recordings, has
Ellen, Segerhag +6 more
openaire +2 more sources