Results 31 to 40 of about 18,987,711 (226)

Assessment of High Speed Spindle Accuracies [PDF]

open access: yes, 2017
The spindle error contributes to 25 percent of the error sources of the work piece in- accuracies. The 70 percent of the spindle errors are due to thermal errors that occurs in the spindle.
A P, Arun   +7 more
core   +1 more source

Effect of preload on the dynamic characteristics of ceramic bearings based on a dynamic thermal coupling model

open access: yesAdvances in Mechanical Engineering, 2020
Ceramic bearings have a good dynamic output performance under an ultra-high, ultra-low temperature due to their small deformation property. Based on the Harris and Palmgren empirical equation, this article establishes the thermal transfer model of a ...
Ke Zhang   +4 more
doaj   +1 more source

A Corrected Adaptive Balancing Approach of Motorized Spindle Considering Air Gap Unbalance

open access: yesApplied Sciences, 2020
Motorized spindles widely used for high-speed precision machine tools are very sensitive to the mass unbalance of rotors; thus, their balancing problem is always a research hotspot.
Hongwei Fan   +5 more
doaj   +1 more source

Thermal Modeling Challenges of High-Speed Motorized Spindles

open access: yes, 2023
AbstractThis paper investigates the thermal modeling challenges of high-speed motorized spindles up to 40,000 rpm. The thermal expansion and deflection of motorized spindles are critical determinants for the resulting tool center point displacement and the achievable machining accuracy of machine tools.
Lukas Koch   +3 more
openaire   +1 more source

Online Dynamic Balance Detection Method of High Speed Motorized Spindle Based on LabVIEW

open access: yes, 2017
Aiming at the dynamic unbalance problem of high speed motorized spindle, an online dynamic balance detection method based on Fourier transform, polynomial curve fitting and Hooke's law is proposed, at the same time, based on virtual instrument LabVIEW ...
Wei Tu, Zhan Wang
core   +1 more source

Organic Electrochemical Transistors for Neuromorphic Bioelectronics: Materials and Manufacturing Technologies

open access: yesAdvanced Science, EarlyView.
Organic electrochemical transistors bridge biological ionic signaling and neuromorphic computation through volumetric electrochemical gating. This review connects Organic mixed ionic–electronic conductor materials, device architectures, and manufacturing technologies to show how geometry, ion transport, and fabrication strategies program plasticity ...
Hyunjin Lee   +5 more
wiley   +1 more source

Optimal Design of Special Fixture for Micro High Speed Motorized Spindle

open access: yes, 2011
The fixture of motorized spindle plays a definitive role in clamping stability and working reliability. If designed irrationally, not only will affect the precision of the micro-milling machines, but also cause the spindle drop.
Xiao Hong Lu, Xu Jia, Zhen Yuan Jia
core   +1 more source

Liquid‐Responsive Shape‐Memory Nanofiber‐Reinforced Scaffolds for Cartilage Repair

open access: yesAdvanced Science, EarlyView.
A liquid‐responsive shape‐memory, nanofiber‐reinforced QCG scaffold combines conformal defect filling, an aligned architecture that is structurally permissive for endogenous cell infiltration, and sustained KGN release. This integrated design enhances BMSC viability, migratory activity, and chondrogenic differentiation and promotes hyaline cartilage ...
Jiyang Zeng   +8 more
wiley   +1 more source

Simulation and experimental study of the thermal characteristics of a high-speed motorized spindle [PDF]

open access: yes
Based on the finite element simulation software ANSYS Workbench, this study reports the thermal characteristics of a high-speed motorized spindle. The temperature field distribution and axial thermal deformation of the motorized spindle are then detected
Zhang, Wei, Jiang, Huaqiao
core   +1 more source

Patient‐Mounted Neuro Optical Coherence Tomography for Targeted Minimally Invasive Micro‐Resolution Volumetric Imaging in Brain In Vivo

open access: yesAdvanced Intelligent Systems, Volume 7, Issue 3, March 2025.
Herein, a patient‐mounted neuro optical coherence tomography system that integrates a 5 degrees‐of‐freedom skull‐mounted robot (Skullbot) with a 0.6 mm neuroendoscope for targeted, minimally invasive deep brain imaging, is developed. The system offers high‐resolution imaging with precise deployment, demonstrated through successful tumor imaging in a ...
Chao Xu   +7 more
wiley   +1 more source

Home - About - Disclaimer - Privacy