Results 241 to 250 of about 16,886,684 (287)
Some of the next articles are maybe not open access.
Difficulties in high frequency transformer modeling
Electric Power Systems Research, 2016Traditional transformer models available in EMTP-like software packages are not capable of representing transformer behavior during a transient state, which includes high frequencies, since they usually do not adequately take into account the transformer resonant behavior caused by its highly complicated design.
Jurišić, Bruno +3 more
openaire +1 more source
High-Voltage, High-Frequency Transformer Design
2012Conversion of AC mains voltages to a high-voltage (>10 kV), high-power (>10 kW) DC level is a key area of technology which is a requirement in many industrial processes, for example, in particulate emission control using electrostatic precipitators. In the majority of cases, this high-voltage DC requirement is achieved with a singlephase AC regulator ...
Paul Lefley, Philip Devine
openaire +1 more source
Transformation of plasmid DNA into Streptomyces at high frequency
Nature, 1978OVER 60% of known antibiotics1 are produced by Streptomyces species, including many substances with valuable clinical and other applications; they therefore have considerable medical, biological and commercial importance. Although the process of gene exchange mediated by conjugation within these actinomycetes is apparently widespread2, the transfer of ...
M J, Bibb, J M, Ward, D A, Hopwood
openaire +2 more sources
Calculation of Leakage Inductance for High-Frequency Transformers
IEEE Transactions on Power Electronics, 2015Frequency-dependent leakage inductance is often observed. The high-frequency eddy current effects cause a reduction in leakage inductance. The proximity effect between adjacent layers is responsible for the reduction of leakage inductance. This paper gives a detailed analysis of high-frequency leakage inductance and proposes an accurate prediction ...
Ouyang, Ziwei +2 more
openaire +1 more source
High voltage, high frequency conversion transformer
IECEC-97 Proceedings of the Thirty-Second Intersociety Energy Conversion Engineering Conference (Cat. No.97CH6203), 2002A 25 kW, 15 kV output, 50 kHz transformer with 100 kV primary to secondary isolation is described. The transformer will be the central element of a resonant inverter. Six of these resonant inverter outputs will be connected in series to produce 90 kV for an airborne application.
C.S. Kerfoot, M.J. Greif
openaire +1 more source
Transformer model for high frequencies
IEEE Transactions on Power Delivery, 1988A method for the development of a high-frequency transformer model for use in an electromagnetic transient program (EMTP) is discussed. A transformer to be modeled is measured, and the results are used to calculate the transfer and admittance functions. Modal analysis is used to determine a no-load network model that can be used in the EMTP.
openaire +1 more source
High frequency models of PCB-based transformers
Proceedings of the 44th IEEE 2001 Midwest Symposium on Circuits and Systems. MWSCAS 2001 (Cat. No.01CH37257), 2002An equivalent network of PCB-based transformers with two windings is presented for use at high frequency (some MHz). After raising some criticisms to the traditional high frequency transformer model, a systematic procedure is presented to deduce the inductive and the capacitive coupling model of a two windings transformer.
ARTURI, CESARE MARIO +1 more
openaire +2 more sources
Frequency Characteristics Analysis of High Frequency Current Transformers
Advanced Materials Research, 2014In this paper, the equivalent model of high frequency current transformers (HFCT) for partial discharge online monitoring and its major parameters’ influence on amplitude-and phase frequency characteristics are derived. An optimized design for HFCT for partial discharge online monitoring is summarized.
Yue Dong +4 more
openaire +1 more source
Optimal design of high-power, mid-high frequency transformer
Proceedings of 2011 International Conference on Electronic & Mechanical Engineering and Information Technology, 2011A high-power, mid-high frequency transformer using silicon steel core is designed for a 30kW, 3 kHz switch-mode power supply (SMPS). Based on the area product method (AP method), the material and type of magnetic core are selected. The winding turns and transformer loss are calculated. The wire specifications are decided.
Gang Wang, Huina Yang
openaire +1 more source
Conjugate Thermal Analysis of a High-Power and High-Frequency Transformer
2010 IEEE Industry Applications Society Annual Meeting, 2010In this paper, a 3D thermal model that couples thermal and flow fields of a high-power, high-frequency oil-immersed transformer was presented. The thermal model including a set of conservation equations was solved using the finite volume method. The temperature and oil flow velocity distribution are of interest.
Ping-Huey Tang +2 more
openaire +2 more sources

