Results 1 to 10 of about 2,310,582 (170)
The macro model of hybrid on-load tap-changer passive trigger [PDF]
Using thyristor as arc medium hybrid on-load tap-changer, completely solve the problem of switch produce arc, reduce the ablation of mechanical contact, improve the working environment of transformer oil, both mechanical switch and brake switch tube, the
Li Peng +6 more
doaj +1 more source
A 3D Printed Ka-Band High-Efficiency Wide-Slit Antenna Array for High-Power Microwave Applications
A Ka-band high-power waveguide wide-slit antenna array with high efficiency and high-power capacity is proposed in this paper. The antenna uses a waveguide vertical transition structure as a part of the feed network, which improves the compactness and ...
Liang Liu +5 more
doaj +1 more source
Development of 110kV Thyristor Assisted Arc Extinguishing Hybrid OLTC [PDF]
On the basis of formulating the technical conditions of 110kV thyristor assisted arc extinguishing hybrid on load tap changer, this paper carries out the mechanical structure design, gives the design scheme of switching switch, selection switch and other
Shi Fei +6 more
doaj +1 more source
Study on internet of things architecture of substation online monitoring equipment [PDF]
This paper introduces the structure of the existing on-line monitoring system, and analyzes the problems of poor compatibility and reliability of IED in different manufacturers.
Zhang Hejun +5 more
doaj +1 more source
Power Macromodeling For High Level Power Estimation [PDF]
A modeling approach is presentedthat captures the dependence of the power dissipationof a combinational logic circuit on its input/outputsignal switching activity.The resultingpower macromodel, consisting of a single three dimensionaltable, can be used to estimate the powerconsumed in the circuit for any given input/outputsignal statistics.Given a low ...
Subodh Gupta, Farid N. Najm
openaire +1 more source
Charging models for airborne suspended particles around HVDC lines
Ground total electric field (GTEF) is a vital parameter in the field of electromagnetic environment of high voltage direct current (HVDC) lines. Some experimental works reported that airborne suspended particles can be charged in the corona ion flow of ...
Kun He +6 more
doaj +1 more source
Research on Defect Diagnosis Method of Reactor Acoustic Vibration Method Based on Deep Learning [PDF]
Although the state evaluation method based on characteristic parameters and weight factors can extract the characteristic quantities in time domain and frequency domain according to the collected acoustic and vibration signals of reactors, it is ...
Jia Peng-fei +5 more
doaj +1 more source
Development and Experimental Research of VFTO Measuring Sensor
Very fast transient overvoltage (VFTO) generated by an operating disconnector is one of the main reasons for electromagnetic disturbance in gas-insulated switchgear (GIS) substations.
Zihan Teng +4 more
doaj +1 more source
Research on GIS Monitoring System in Operation Based on Rail Robot [PDF]
GIS is prone to various defects and faults after putting into operation, and the failure rate is high. At present, the inspection methods of GIS in operation include traditional inspection mode, two-dimensional code inspection mode, radio frequency ...
Jia Peng-Fei +5 more
doaj +1 more source
Power modeling for high-level power estimation [PDF]
In this paper, we propose a modeling approach that captures the dependence of the power dissipation of a combinational logic circuit on its input/output signal switching statistics. The resulting power macromodel, consisting of a single four-dimensional table, can be used to estimate the power consumed in the circuit for any given input/output signal ...
Subodh Gupta, Farid N. Najm
openaire +1 more source

