Results 101 to 110 of about 137,232 (346)

Population of Nonmetallic Inclusions in Liquid High‐Silicon Electrical Steel in Contact With MgO–C Refractories Based on Recyclates and Environmentally Friendly Binders

open access: yesAdvanced Engineering Materials, EarlyView.
The formation of nonmetallic inclusions (NMIs) was investigated in this study, carrying out immersion tests for 30 min at a temperature of 1600°C with liquid high‐silicon electrical steel (Si ≈ 3 mass‐%) and different MgO–C refractories. Conventional MgO–C refractories were considered, as well as MgO–C refractories containing MgO–C recyclate and ...
Lukas Neubert   +6 more
wiley   +1 more source

Investigation of Oxygen‐Free Wetting Behavior of Aluminum on Copper via Molecular Dynamics Simulations and Experiments

open access: yesAdvanced Engineering Materials, EarlyView.
The wettability of aluminum droplets (Al) on different copper substrates (Cu), where liquid Al spreads on solid Cu surfaces to form a liquid–solid interface, is studied numerically and experimentally. The experimental and numerical results show good agreement in the fast‐spreading regime.
Shan Lyu   +8 more
wiley   +1 more source

Dynamic Testing of Cold Gas Sprayed Bipolar Plates–Porous Transport Layer Coating System in Proton Exchange Membrane Water Electrolysis

open access: yesAdvanced Engineering Materials, EarlyView.
Through direct application of porous transport layer (PTL) on the bipolar plate (BPP) with thermal spraying, the interfacial contact resistance is improved. With the cold gas sprayed BPP–PTL coating system, a proton exchange membrane water electrolysis cell with a cell voltage of Ucell = 1.9 V can be operated up to i = 2.5 A/cm2 in a dynamic mode ...
Kirsten Bobzin   +5 more
wiley   +1 more source

Research on identification method of abnormal grounding circulating current in single‐core AC submarine cable

open access: yesIET Generation, Transmission & Distribution
The grounding circulation current of the sheath and armour of single‐core AC submarine cables is high during operation, which can easily cause insulation damage and faults.
Yuxin Yang   +3 more
doaj   +1 more source

A Novel High-Frequency Voltage Standing-Wave Ratio-Based Grounding Electrode Line Fault Supervision in Ultra-High Voltage DC Transmission Systems

open access: yesEnergies, 2017
In order to improve the fault monitoring performance of grounding electrode lines in ultra-high voltage DC (UHVDC) transmission systems, a novel fault monitoring approach based on the high-frequency voltage standing-wave ratio (VSWR) is proposed in this ...
Yufei Teng   +6 more
doaj   +1 more source

Corrosion and Process Analysis of a Preoxidized MgO Recyclate‐Based Cermet Anode in Laboratory‐Scale Na‐Cryolite Molten Salt Electrolysis of Aluminum at 1000°C

open access: yesAdvanced Engineering Materials, EarlyView.
EDX elemental map of the pre‐oxidized MgO–steel cermet anode cross section after electrolysis. The development of inert anodes for aluminum electrolysis remains challenging due to the high corrosivity of cryolite‐based melts at 950°C–1000°C. This study investigates the corrosion and process behavior of a carbon‐free MgO–steel cermet anode derived from ...
Alexander Adamczyk   +7 more
wiley   +1 more source

Pyramidal Structures on Yttria‐Stabilized Zirconia after High Temperature Exposure at 1500°C: New Features on an Old Material

open access: yesAdvanced Engineering Materials, EarlyView.
New features on yttria‐stabilized zirconia after exposure at 1500°C: Newly discovered pyramidal structures on an old material. After exposure at 1550°C on the cross section of YSZ new features, namely pyramidal structures are discovered. These structures grow with time, increase in numbers, appear as singularities, are often arranged in strings, and ...
Doris Sebold   +2 more
wiley   +1 more source

Topolectrical circuits

open access: yes, 2017
Invented by Alessandro Volta and F\'elix Savary in the early 19th century, circuits consisting of resistor, inductor and capacitor (RLC) components are omnipresent in modern technology. The behavior of an RLC circuit is governed by its circuit Laplacian,
Bayer, Florian   +7 more
core   +1 more source

A Knowledge‐Based Approach for Understanding and Managing Additive Manufacturing Data

open access: yesAdvanced Engineering Materials, EarlyView.
Additive manufacturing processes generate a large amount of data. Effectively managing, understanding, and retrieving information from this data remains a major challenge. Therefore, we propose an ontology‐based approach to integrate heterogeneous data, enable semantic queries, and support decision‐making.
Mina Abd Nikooie Pour   +5 more
wiley   +1 more source

Electromagnetic compatibility in myoelectrode amplifiers: Isolation, impedance and CMRR [PDF]

open access: yes, 2010
SUMMARY: Electromagnetic compatibility of myoelectrode amplifiers for prosthetic control is important for safe operation in electrically noisy conditions.
Poulton, Adrian
core  