Results 151 to 160 of about 12,309 (233)

A Novel 3D‐Printed Strut‐Type Prosthesis Reconstructs the Hemicortical Defect After Distal Femur Parosteal Osteosarcoma Resection: The Mid‐Term Follow‐Up Outcome

open access: yesOrthopaedic Surgery, Volume 18, Issue 8, Page 1668-1678, August 2026.
This study developed a novel three‐dimensional (3D)‐printed strut‐type prosthesis for reconstruction of bone defects following hemicortical resection of distal femoral parosteal osteosarcoma. The mid‐term follow‐up results demonstrated that this prosthesis effectively restored limb function and exhibited favorable bone ingrowth and osseointegration ...
Jianhua Mu   +10 more
wiley   +1 more source

The Effect of the Coronal Alignment of Extension Stem on Component Displacement and Stress During Total Knee Arthroplasty: A Finite Element Study

open access: yesOrthopaedic Surgery, Volume 18, Issue 8, Page 1679-1687, August 2026.
Kinematic alignment (KA) increases prosthesis displacement and reduces stress shielding in total knee arthroplasty (TKA), while short extension stems reduce prosthesis displacement but increase stress shielding, and their combination may have complementary effects. This requires further research to confirm.
Lingce Kong   +6 more
wiley   +1 more source

High‐Fidelity Measurement‐Based Detection Values and Roles of Three‐Dimensional Joint Space Width in Evaluation of Knee Osteoarthritis

open access: yesOrthopaedic Surgery, Volume 18, Issue 8, Page 1710-1733, August 2026.
A 0.1 mm reference mesh defines resolution thresholds for 3D joint space width mapping in medial knee osteoarthritis across KL 0–4. To balance fidelity and practicality, a 0.3 mm mesh provides the most consistent performance across conditions; 0.5 mm is acceptable under a less stringent error tolerance for medJSW; and up to 1.0 mm is suitable only for ...
Elena Tahir   +5 more
wiley   +1 more source

Locked plate versus modified clamp‐rod internal fixation for feline corpus ilium fractures: A comparative clinical study

open access: yesVeterinary Surgery, Volume 55, Issue 6, Page 1133-1142, August 2026.
Abstract Objective To evaluate the applicability and clinical effectiveness of a modified clamp‐rod internal fixation (M‐CRIF) system compared with conventional locking plate osteosynthesis in the treatment of feline corpus ilium fractures. Study design Prospective, controlled clinical study.
Nahit Saylak   +4 more
wiley   +1 more source

High tibial osteotomy in geriatric patients with gonarthrosis. [PDF]

open access: yesBMC Geriatr
Akar B   +4 more
europepmc   +1 more source

Distal femoral varus deformity becomes a cause of undercorrection in open wedge high tibial osteotomy. [PDF]

open access: yesJ Exp Orthop
Maeyama A   +5 more
europepmc   +1 more source

Accuracy of osteotomy in high tibial osteotomy

open access: yesThe Central Japan Journal of Orthopaedic Surgery & Traumatology, 2003
openaire   +1 more source

Home - About - Disclaimer - Privacy