High-voltage oil circuit breakers
Electrical Engineering, 1950ONLY a few years ago, 3,500,000 kva was the maximum standard rated interrupting capacity for high-voltage circuit breakers, and the interrupting-time ratings were mostly five and eight cycles. This article describes recent developments in interrupting devices that have made available standard circuit breakers for 5,000,000-kva interrupting capacity and
W. M. Leeds, R. E. Friedrich
openaire +1 more source
Timings of high voltage circuit-breaker
Electric Power Systems Research, 2008The reliability of an electrical power system is influenced by the operation of circuit-breaker (CB). A good indicator of circuit-breaker condition is its switching time. Based on it some of the critical circuit-breaker irregularities can be detected and removed before they develop to a failure.
Bartosz Rusek +3 more
openaire +1 more source
Cascaded SiC JFET Topology for High-Voltage Solid-State Circuit Breaker Applications
IEEE transactions on industry applications, 2023With evolving landscape of direct current (DC) power transmission and distribution, a reliable and fast protection against faults is critical. High performance DC solid-state circuit breakers (SSCBs) can be designed using silicon carbide (SiC) junction ...
L. G. Garcia Rodriguez +8 more
semanticscholar +1 more source
Interrupters for high-voltage circuit breakers
Electrical Engineering, 1957The demand for higher breaker voltages and interrupting ratings created by today's expanding energy requirements presents numerous design and test problems. A new line of high-power tubular multibreak-type interrupters has been developed, features of which include accessibility, simplicity of replacement, and a design that can be verified by part ...
A. W. Hill, R. E. Friedrich
openaire +1 more source
IEEE transactions on consumer electronics
Clearance joints can reduce motion accuracy and shorten service life for high-voltage circuit breakers, and they are a significant source of mechanical faults. For clearance joint fault diagnosis, the anti-interference ability is important.
Xiaofeng Li +5 more
semanticscholar +1 more source
Clearance joints can reduce motion accuracy and shorten service life for high-voltage circuit breakers, and they are a significant source of mechanical faults. For clearance joint fault diagnosis, the anti-interference ability is important.
Xiaofeng Li +5 more
semanticscholar +1 more source
IEEE Sensors Journal, 2019
The working condition of opening damper directly affects the opening mechanical characteristics and component lifetime of high-voltage circuit breaker (HVCB). Vibration diagnostic technique is a noninvasive and efficient way for on-line evaluation of the
Qiuyu Yang +3 more
semanticscholar +1 more source
The working condition of opening damper directly affects the opening mechanical characteristics and component lifetime of high-voltage circuit breaker (HVCB). Vibration diagnostic technique is a noninvasive and efficient way for on-line evaluation of the
Qiuyu Yang +3 more
semanticscholar +1 more source
IEEE International Conference on High Voltage Engineering and Application, 2020
Limited by the characteristics of the device itself and the number of fault samples, the research of high-voltage circuit breaker mechanical fault diagnosis technology is relatively difficult.
Jing Yan, Yanxin Wang
semanticscholar +1 more source
Limited by the characteristics of the device itself and the number of fault samples, the research of high-voltage circuit breaker mechanical fault diagnosis technology is relatively difficult.
Jing Yan, Yanxin Wang
semanticscholar +1 more source
Transactions of the American Institute of Electrical Engineers, 1923
The 150-kv. system operated for some years by the Southern California Edison Company has not made use of automatic operation of circuit breakers. The multiplication of generating stations and connections which accompanied the change to 220-kv. makes desirable the automatic sectionalizing of the line in cases of trouble and, therefore, requires circuit ...
openaire +1 more source
The 150-kv. system operated for some years by the Southern California Edison Company has not made use of automatic operation of circuit breakers. The multiplication of generating stations and connections which accompanied the change to 220-kv. makes desirable the automatic sectionalizing of the line in cases of trouble and, therefore, requires circuit ...
openaire +1 more source
Acoustic diagnosis of high voltage circuit-breakers
IEEE Transactions on Power Delivery, 1992A noninvasive technique for assessing the condition of circuit breakers by considering the acoustic signals generated during nonenergized switching is described. Mechanical malfunction, wear, and other types of abnormal behavior can be detected as changes in this acoustic signature.
M. Runde +4 more
openaire +1 more source
CNN based Mechanical Fault Diagnosis of High Voltage Circuit Breaker using Sound and Current Signal
IEEE International Conference on High Voltage Engineering and Application, 2020High voltage circuit breaker is a critical equipment of power system. It is very important to ensure the circuit breaker to operate in a normal state. According to statistics, most defect and fault of high voltage circuit breaker is caused by mechanical ...
Xiaoming Wang +3 more
semanticscholar +1 more source