Topology assessment for 3 + 3 terminal offshore DC grid considering DC fault management [PDF]
Peer ...
Jovcic, Dragan +3 more
core +1 more source
Investigations into the Influence of generator Design on Rating of Circuit Breakers in a High Voltage Transmission Network [PDF]
This paper examines the impact of the network modification produced by the replacement of an existing conventional generator with a high voltage directly connected generator on the adequacy of existing circuit breakers distributed throughout a high ...
McDonald, J. D. F., Saha, T. K.
core +1 more source
System configuration, fault detection, location, isolation and restoration: a review on LVDC Microgrid protections [PDF]
Low voltage direct current (LVDC) distribution has gained the significant interest of research due to the advancements in power conversion technologies. However, the use of converters has given rise to several technical issues regarding their protections
Bououden +11 more
core +1 more source
Superconducting fault current limiter application in a power-dense marine electrical system [PDF]
Power-dense, low-voltage marine electrical systems have the potential for extremely high fault currents. Superconducting fault current limiters (SFCLs) have been of interest for many years and offer an effective method for reducing fault currents.
Blair, Steven Macpherson +5 more
core +1 more source
The development of power grid system not only increases voltage and capacity, but also increases power risk. This paper briefly introduces the feature extraction method of the vibration signal of high voltage circuit breaker and support vector machine ...
Li Long +4 more
doaj +1 more source
Tripping of circuit breakers in PV installations due to zero sequence field impedance [PDF]
On the roof of a wool processing company a 385 kWp PV installation is installed. When production of the installation is more than 60% of the rated power the circuit breaker trips.
Debruyne, Colin +3 more
core +2 more sources
Experimental Test bed to De-Risk the Navy Advanced Development Model [PDF]
This paper presents a reduced scale demonstration test-bed at the University of Texas’ Center for Electromechanics (UT-CEM) which is well equipped to support the development and assessment of the anticipated Navy Advanced Development Model (ADM).
Feng, X +6 more
core +1 more source
Basic contents of on-line monitoring technologies of mechanical characteristics of high-voltage vacuum circuit breaker were introduced, and various kinds of methods of on-line monitoring were reviewed.
ZHAO Yang
doaj +1 more source
Fault mode operation strategies for dual H-bridge current flow controller in meshed HVDC grid [PDF]
Peer ...
Carvalho, Adriano +5 more
core +2 more sources
Mechanism Analysis and Simulation Study of Closing Overvoltage Fault in EMU Circuit Breaker
Objective The overvoltage caused by circuit breaker closing will aggravate the insulation aging of high voltage equipment when EMU (electric multiple units)passes neutral section.
ZHANG Mingrui +2 more
doaj +1 more source